Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman Furnace Error Codes

Updated · by Aurora Star Tech Inc.

131 Goodman Furnace error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Goodman Furnace error codes list

CodeMeaningSeverity
1 flashLockout - three failed ignition triesHigh
1ACCooling, low stageLow
2 flashesPressure switch stuck closedHigh
2ACCooling, high stageLow
3 flashesPressure switch stuck openHigh
4 flashesPrimary or auxiliary limit openHigh
5 flashesFlame sensed with no call for heatCritical
6 flashesRollout limit open or control fuse blownHigh
7 flashesLow flame signalMedium
8 flashesIgniter relay faultHigh
9 flashesTwinning faultMedium
10 flashesOpen fuse - no 24 V at the controlMedium
11 flashesIgniter openHigh
12 flashesInducer relay faultHigh
88Power-up self checkLow
ACCooling, single stageLow
AC1Cooling, low stage (communicating)Low
AC2Cooling, high stage (communicating)Low
AxxAirflow readoutLow
b0Blower motor not runningHigh
b1Lost communication with blower motorHigh
b2Blower motor size does not match model dataMedium
b3Blower motor limiting (power, temperature or speed)Medium
b4Blower motor trip (lost rotor control or high current)High
b5Blower motor locked rotorHigh
b6Blower motor over/under voltage or over temperatureHigh
b7Blower motor missing parametersMedium
b9Low indoor airflowMedium
C1Low-stage coolingLow
C2High-stage coolingLow
CFM readoutAirflow number (CFM / 100)Low
CFSComfort settingLow
CrCode release numberLow
d0No shared data on the controlHigh
d4Memory card data rejectedMedium
dF1Defrost, low-stage gas heatLow
dF2Defrost, high-stage gas heatLow
dHLDehumidify logic input levelLow
dHUDehumidifier onLow
E0Lockout - ignition failed 3 timesHigh
E1Low-stage pressure switch closed at start of heatMedium
E2Low-stage pressure switch will not closeHigh
E3High limit or rollout limit openHigh
E4Flame sensed with no call for heatCritical
E5Control fuse openMedium
E6Low flame signalLow
E7Igniter circuit faultHigh
E8High-stage pressure switch closed at start of heatMedium
E9High-stage pressure switch will not closeMedium
E10Grounding fault / poor neutral connectionHigh
E11Flame rollout switch openCritical
E12Redundant relay openHigh
E13Redundant relay stuck closedHigh
EA115 V polarity reversedHigh
Eb0Blower motor not runningHigh
Eb1Lost communication with blower motorHigh
Eb2Blower motor hp does not match model dataMedium
Eb3Blower motor running in power, temperature or speed limitMedium
Eb4Blower motor current trip or lost rotor controlHigh
Eb5Blower motor locked rotorHigh
Eb7Blower motor missing parametersHigh
Eb9Inadequate airflowMedium
Ec1Network communication alarmMedium
Ec2E-module network communication alarmMedium
Ec3Bluetooth module network communication alarmLow
Ed0No shared data on the networkMedium
Ed1Invalid data on networkMedium
Ed4Memory card data rejectedMedium
Ed5Invalid downloaded firmwareMedium
Ed6Unrecognized data IDMedium
EE0Lockout - too many ignition retries (3)High
EE1Pressure switch closed at start of heating cycleMedium
EE2Pressure switch did not close (inducer runs, no ignition)Medium
EE3High (primary) limit openHigh
EE4Flame sensed with no call for heatCritical
EE5Open fuse (short in low voltage wiring)Medium
EE6Low flame signalLow
EE8High-stage pressure switch closed at start of heating cycleMedium
EE9High-stage pressure switch did not closeMedium
EEAReversed line polarity or grounding errorHigh
EEbExternal gas valve error - valve not energized when it should beHigh
EECInternal gas valve error - valve energized when it should not beCritical
EEdCondensate or auxiliary alarm switch openMedium
EEEInternal control fault (IRQ loss)High
EEFCondensate switch openMedium
EEHTwinning errorLow
EEJInducer relay errorHigh
EELIgniter relay / igniter circuit faultHigh
EEnIgniter openHigh
EOLOEM test modeLow
ErrActive alarm menuLow
FContinuous fanLow
FAnContinuous fanLow
gAFGas heat airflowLow
gbPBackup heat balance pointsLow
gFdGas heat fan off delayLow
gHGas heat, single stageLow
gH1Gas heat, low stageLow
gH2Gas heat, high stageLow
gndGas heat fan on delayLow
gPtGas pressure testLow
gStGas heat stage multiplierLow
gtFGas heat trim factorLow
HEdHumidifier enableLow
HIHigh-stage heatLow
HPHeat pump heat, single stageLow
HP1Heat pump heat, low stageLow
HP2Heat pump heat, high stageLow
HUdHumidifier onLow
IdLIdle - no callLow
L0Low-stage heatLow
L6FLast 6 faults (view and clear)Low
LED offNo LED - no power or control failureHigh
LED steady onNormal operationLow
LrnLearn menuLow
OPNormal - waiting for a callLow
Rapid flashReversed polarityHigh
Red LED 1 flashRed communications LED 1 flash - communication failureMedium
Red LED 2 flashesRed communications LED 2 flashes - reset in progressLow
Red LED offRed communications LED off - normalLow
rFdReset to factory defaultsLow
Rx LED 1 steady flashGreen receive LED single steady flash - no network foundLow
Rx LED offGreen receive LED off - no power or communications errorMedium
Rx LED on solidGreen receive LED on solid - data lines miswired or shortedMedium
Rx LED rapid flashGreen receive LED rapid flashing - normal network trafficLow
SH1Special heat relay 1Low
SH2Special heat relay 2Low
SrShared data revisionLow
uACInverter coolingLow
uHPInverter heat pump heatLow
utLVentilator onLow

Find codes by Goodman model

Goodman/Amana *MVC96 (34.5 in. chassis)

*CVC960403BNB**CVC960603BNB**CVC960804CNB**CVC961005CNB**CVC961205DNB**MVC960403BNB**MVC960603BNB**MVC960803BNB**MVC960804CNB**MVC961005CNB**MVC961005DNB**MVC961205DNB*ACVC96AMVC96GCVC96GMVC96

Goodman/Amana GM9C96/AM9C96

AC9C96AM9C96AM9C960303ANGC9C96GM9C96GM9C960303AN

Goodman/Amana GM9S80/AM9S80

AC9S800403ANAC9S800603ANAC9S800804BNAC9S800805CNAC9S801005CNAM9S800403ANAM9S800603ANAM9S800603BNAM9S800604BNAM9S800803BNAM9S800804BNAM9S800804CNAM9S800805CNAM9S801005CNAM9S801205DNGC9S800403ANGC9S800603ANGC9S800804BNGC9S800805CNGC9S801005CNGM9S800403ANGM9S800603ANGM9S800603BNGM9S800604BNGM9S800803BNGM9S800804BNGM9S800804CNGM9S800805CNGM9S801005CNGM9S801205DN

Goodman/Amana GM9S96/AM9S96

AC9S960403BNAC9S960603BNAC9S960804CNAC9S961005CNAC9S961205CNAC9S961205DNAM9S920403ANAM9S920603BNAM9S920803BNAM9S920804CNAM9S920805CNAM9S921004CNAM9S921005CNAM9S921205DNAM9S960403ANAM9S960603BNAM9S960803BNAM9S960804CNAM9S960805CNAM9S961004CNAM9S961005CNAM9S961205DNGC9S960403BNGC9S960603BNGC9S960804CNGC9S961005CNGC9S961205CNGC9S961205DNGM9S920403ANGM9S920603BNGM9S920803BNGM9S920804CNGM9S920805CNGM9S921004CNGM9S921005CNGM9S921205DNGM9S960403ANGM9S960603BNGM9S960803BNGM9S960804CNGM9S960805CNGM9S961004CNGM9S961005CNGM9S961205DN

Goodman/Amana *MES9 single-stage

ACES96ACES960403BNAAACES960603BNAAACES960804CNAAACES961005CNAAACES961205DNAAAMES92AMES96AMES920403ANAAAMES920603BNAAAMES920803BNAAAMES920804CNAAAMES920805CNAAAMES921004CNAAAMES921005CNAAAMES921205DNAAAMES960403ANAAAMES960603BNAAAMES960803BNAAAMES960804CNAAAMES960805CNAAAMES961005CNAAAMES961205DNAAGCES96GCES960403BNAAGCES960603BNAAGCES960804CNAAGCES961005CNAAGCES961205DNAAGMES92GMES96GMES920403ANAAGMES920603BNAAGMES920803BNAAGMES920804CNAAGMES920805CNAAGMES921004CNAAGMES921005CNAAGMES921205DNAAGMES960403ANAAGMES960603BNAAGMES960803BNAAGMES960804CNAAGMES960805CNAAGMES961005CNAAGMES961205DNAAVCES96VCES960403BNAAVCES960603BNAAVCES960804CNAAVCES961005CNAAVMES96VMES960403ANAAVMES960603BNAAVMES960803BNAAVMES960804CNAAVMES961005CNAA

Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Furnace troubleshooting guides

Goodman Furnace specs and setup data

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977