Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman Error Code E5: Control fuse open (Furnace)

Updated · by Aurora Star Tech Inc.

Goodman error code E5 on a furnace means: Control fuse open. It is also called Goodman diagnostic code E5.

Medium severityFurnaceGoodman/Amana *MVC95/*CVC9 two-stage ComfortNet

Homeowner? What Goodman code E5 means for you

Check, then call Your furnace is reporting: Control fuse open. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code E5 mean?

The 3 A fuse on the control board is blown, usually from a short in the 24 V wiring. A ComfortNet thermostat runs on battery power and shows Battery Power.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Common causes of Goodman code E5

  • Short in the low voltage wiring (thermostat, outdoor unit, accessories)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code E5

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other Goodman Furnace codes

CodeMeaning
d4Memory card data rejected
E0Lockout - ignition failed 3 times
E1Low-stage pressure switch closed at start of heat
E2Low-stage pressure switch will not close
E3High limit or rollout limit open
E4Flame sensed with no call for heat
E6Low flame signal
E7Igniter circuit fault
E8High-stage pressure switch closed at start of heat
E9High-stage pressure switch will not close
E10Grounding fault / poor neutral connection
E11Flame rollout switch open

All Goodman Furnace error codes →

Goodman code E5: homeowner questions

What does Goodman code E5 mean?

Control fuse open. The 3 A fuse on the control board is blown, usually from a short in the 24 V wiring. A ComfortNet thermostat runs on battery power and shows Battery Power.

Is it safe to keep using my furnace with code E5?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Goodman code E5 myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code E5 comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code E5 near me?

Aurora Star Tech Inc. repairs Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Troubleshooting Chart p.53-57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977