Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman Error Code d0: No shared data on the control (Furnace)

Updated · by Aurora Star Tech Inc.

Goodman error code d0 on a furnace means: No shared data on the control. It is also called Goodman diagnostic code d0.

High severityFurnaceGoodman/Amana *MVC95/*CVC9 two-stage ComfortNet

Homeowner? What Goodman code d0 means for you

Call a technician Your furnace is reporting: No shared data on the control. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code d0 mean?

The control has no model data (shared data) loaded, so the furnace will not run. ComfortNet thermostat shows NO NET DATA d0.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Common causes of Goodman code d0

  • Shared data never loaded (often after a control replacement)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code d0

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other Goodman Furnace codes

CodeMeaning
b7Blower motor missing parameters
b9Low indoor airflow
C1Low-stage cooling
C2High-stage cooling
CFM readoutAirflow number (CFM / 100)
CrCode release number
d4Memory card data rejected
E0Lockout - ignition failed 3 times
E1Low-stage pressure switch closed at start of heat
E2Low-stage pressure switch will not close
E3High limit or rollout limit open
E4Flame sensed with no call for heat

All Goodman Furnace error codes →

Goodman code d0: homeowner questions

What does Goodman code d0 mean?

No shared data on the control. The control has no model data (shared data) loaded, so the furnace will not run. ComfortNet thermostat shows NO NET DATA d0.

Is it safe to keep using my furnace with code d0?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Goodman code d0 myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code d0 comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code d0 near me?

Aurora Star Tech Inc. repairs Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Troubleshooting Chart p.53-57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977