Goodman Error Code EEd: Condensate or auxiliary alarm switch open (Furnace)

Updated · by Aurora Star Tech Inc.

Goodman error code EEd on a furnace means: Condensate or auxiliary alarm switch open. It is also called Goodman diagnostic code EEd.

Medium severityFurnaceACVC96 · AMVC96 · GCVC96 · GMVC96

Homeowner? What Goodman code EEd means for you

Check, then call Your furnace is reporting: Condensate or auxiliary alarm switch open. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code EEd mean?

The AUX switch input has opened, which means the evaporator base pan water level is too high. The control turns off the outdoor condensing unit and shows EEd. Normal operation returns and the message clears once the switch has been closed for 30 seconds.

Applies to: All 34.5in chassis furnaces with condensate switch

Common causes of Goodman code EEd

  • Blocked or slow condensate drain or trap
  • Water level too high in the evaporator coil base pan
  • Condensate switch open or wired wrong
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Goodman Furnace codes

CodeMeaning
EE7Igniter circuit fault or poor ground
EE8High-stage pressure switch closed at start of heating cycle
EE9High-stage pressure switch did not close
EEAReversed line polarity or grounding error
EEbExternal gas valve error - valve not energized when it should be
EECInternal gas valve error - valve energized when it should not be
EEEInternal control fault (IRQ loss)
EEFCondensate switch open
EEHTwinning error
EEJInducer relay error
EELIgniter relay / igniter circuit fault
EEnIgniter open

All Goodman Furnace error codes →

Goodman code EEd: homeowner questions

What does Goodman code EEd mean?

Condensate or auxiliary alarm switch open. The AUX switch input has opened, which means the evaporator base pan water level is too high. The control turns off the outdoor condensing unit and shows EEd. Normal operation returns and the message clears once the switch has been closed…

Is it safe to keep using my furnace with code EEd?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Goodman code EEd myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code EEd comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code EEd near me?

Aurora Star Tech Inc. repairs Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Goodman GMVC96 service and troubleshooting manual, p. 32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977