Goodman Furnace: Bypass the inductor to test an ECM motor

Updated · by Aurora Star Tech Inc.

Bypass the inductor to test an ECM motor on a Goodman furnace: The inductor is in the line power supply to the motor. If it has failed, the motor will not run.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 3/4 and 1 HP ECM motors with inductor

How to fix bypass the inductor to test an ecm motor: step by step

  1. Disconnect the black line wire from the inductor.
  2. Connect that wire directly to the motor.
  3. If the motor runs, replace the inductor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Furnace codes

More other tips for furnace

Source: Goodman GMVC96 service and troubleshooting manual, p. 44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.