Goodman Furnace: Standard furnace vent and intake connections

Updated · by Aurora Star Tech Inc.

Standard furnace vent and intake connections on a Goodman furnace: The vent outlet takes 2 in. pipe and is glued into the furnace fitting, or a short 2 in. section can be glued in with a rubber coupling for service removal. Route piping away from refrigerant lines, metering devices and condensate lines. Two 45-degree long-sweep elbows make an offset that counts as one 90-degree elbow.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vent/flue connections

How to fix standard furnace vent and intake connections: step by step

  1. Glue the vent pipe into the furnace fitting, or use a short glued section and rubber coupling.
  2. Route vent and intake pipe clear of refrigerant lines, metering devices and condensate drains.
  3. Use two 45-degree long-sweep elbows if extra clearance is needed; count as one 90-degree elbow.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Furnace codes

More commissioning tips for furnace

Source: Goodman GMVC96 service and troubleshooting manual, p. 14. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.