Goodman Error Code E4: Flame sensed with no call for heat (Furnace)

Updated · by Aurora Star Tech Inc.

Goodman error code E4 on a furnace means: Flame sensed with no call for heat. It is also called Goodman diagnostic code E4.

Critical severityFurnaceGoodman/Amana *MVC95/*CVC9 two-stage ComfortNet

Homeowner? What Goodman code E4 means for you

Stop and call Your furnace is reporting: Flame sensed with no call for heat. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code E4 mean?

The control sees flame when the gas valve should be closed. Inducer and blower both keep running. ComfortNet thermostat shows IMPROPER FLAME E4.

Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces

Common causes of Goodman code E4

  • Flame sensor or its wire shorted to ground
  • Burner flame lingering after shutdown
  • Gas valve slow to close
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code E4

GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX

Other Goodman Furnace codes

CodeMeaning
d0No shared data on the control
d4Memory card data rejected
E0Lockout - ignition failed 3 times
E1Low-stage pressure switch closed at start of heat
E2Low-stage pressure switch will not close
E3High limit or rollout limit open
E5Control fuse open
E6Low flame signal
E7Igniter circuit fault
E8High-stage pressure switch closed at start of heat
E9High-stage pressure switch will not close
E10Grounding fault / poor neutral connection

All Goodman Furnace error codes →

Goodman code E4: homeowner questions

What does Goodman code E4 mean?

Flame sensed with no call for heat. The control sees flame when the gas valve should be closed. Inducer and blower both keep running. ComfortNet thermostat shows IMPROPER FLAME E4.

Is it safe to keep using my furnace with code E4?

No. Code E4 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Goodman code E4 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Goodman code E4 near me?

Aurora Star Tech Inc. repairs Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Troubleshooting Chart p.53-57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.