Daikin Error Codes & Diagnostic Codes

Updated · by Aurora Star Tech Inc.

Daikin error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Daikin error codes by equipment type

Daikin Air Conditioner error codes

CodeMeaning
14Repeated high pressure faults (minor)
16Repeated low pressure faults (minor)
33Outdoor control board overheating (minor)
52Repeated compressor faults (minor)
53Repeated outdoor fan / board faults (minor)
54Repeated low discharge superheat faults (minor)
55Repeated high discharge temperature faults (minor)
57Sweating on the board cooling loop
CoreSense 1CoreSense: yellow 1 flash, long run time
CoreSense 2CoreSense: 2 flashes, pressure trip (yellow alert / red lock)
CoreSense 3CoreSense: 3 flashes, short cycling (yellow alert / red lock)
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)
CoreSense 5CoreSense: 5 flashes, moderate run trip (yellow alert / red lock)
CoreSense 9CoreSense: red 9 flashes, PROT terminal over current
CoreSense solid redCoreSense: solid red TRIP
CoreSense solid yellowCoreSense: solid yellow RUN
CoreSense TRIP+ALERT flashingCoreSense: TRIP and ALERT flashing together
E11System start-up test not done
E12Control board memory error
E13Repeated high pressure faults (critical)
E15Repeated low pressure faults (critical)
E17Repeated compressor faults (critical)
E18Control board may need replacing (outdoor fan drive)
E19Repeated outdoor fan / board faults (critical)
E20Outdoor EEV fault
E21Repeated low discharge superheat faults
E22Repeated high discharge temperature faults
E23Discharge temperature sensor out of range
E24High pressure switch open
E25Outdoor air temperature sensor open or shorted
E26Pressure sensor not responding
E27Outdoor coil defrost sensor out of range
E28Outdoor coil temperature sensor out of range
E29Liquid temperature sensor out of range
E30Control board may need replacing
E32Outdoor control board overheating (critical)
E34High current detected
E35High current, possible short circuit
E36Abnormal start-up
E37Control board may need replacing (fan motor link)
E38Compressor voltage problem
E39Control board may need replacing (thermistor input)
E40Compressor setup does not match the unit
E41Low refrigerant
E42Low supply voltage
E43High supply voltage
E44Outdoor temperature out of operating range
E47System verification test blocked by indoor heat
E49Charging mode blocked by indoor heat
E50Voltage problem on the control board
E51Communication problem seen by the outdoor board
E56Suction temperature sensor out of range
E58Compressor overload (OL) sensor open
Eb0Indoor airflow near zero
Eb9Indoor airflow below what is needed
Ed0No shared data on the control
Ed1Bad shared or network data
Ed2Airflow needed is more than the indoor unit can give
Ed3Shared data does not match the hardware
Ed4Memory card data rejected
Green Rx LED 1 steady flashNetwork: no network found
Green Rx LED offNetwork: no power or no communication
Green Rx LED on solidNetwork: terminal 1 / 2 miswired
Red comm LED 1 flashNetwork: communications failure
Red comm LED 2 flashesNetwork: out-of-box reset

Daikin Air Handler error codes

CodeMeaning
9bLow indoor airflow (with electric heat)
70EEV disconnection detected
73Liquid side thermistor abnormality
74Gas side thermistor abnormality
75Pressure sensor abnormality
76Indoor unit to outdoor unit / gas furnace / blower communication error (during operation)
77Indoor unit to thermostat communication error (start-up and during operation)
78Indoor unit to outdoor unit / gas furnace / blower communication error (start-up operation)
b4Blower motor current trip or lost rotor
b7ID blower motor missing required parameters, fails to start
b9Low indoor airflow (without electric heat)
E76No outdoor unit or indoor unit communication
E77No thermostat communication
E78No outdoor unit or indoor unit communication
Eb0Estimated indoor airflow near zero CFM
Eb9Indoor airflow below requirement
EdElectric heater DIP switches not matched to heater kit
Ed2System mismatch
EEEmergency operation indicator

Daikin Furnace error codes

CodeMeaning
1ACCooling, low stage
2ACCooling, high stage
A2uR-32 leak function test
CrCode release number
E10Grounding fault / poor neutral connection
E11Flame rollout switch open
EAFR-32 sensor communication lost - mitigation mode
EALR-32 refrigerant leak detected - mitigation mode
EArA2L relay fault - mitigation mode
EASR-32 sensor fault - mitigation mode
EbLLow circulator current - hard lockout
EbUUnexpected circulator current - hard lockout
EE0Lockout - too many ignition retries (3)
EE1Pressure switch closed at start of heating cycle
EE2Pressure switch did not close (inducer runs, no ignition)
EE3High (primary) limit open
EE4Flame sensed with no call for heat
EE5Open fuse (short in low voltage wiring)
EE6Low flame signal
EE8High-stage pressure switch closed at start of heating cycle
EE9High-stage pressure switch did not close
EEAReversed line polarity or grounding error
EEbExternal gas valve error - valve not energized when it should be
EECInternal gas valve error - valve energized when it should not be
EEEInternal control fault (IRQ loss)
EEHTwinning error
EEJInducer relay error
EELIgniter relay / igniter circuit fault
EEnIgniter open
EOLOEM test mode
ErrActive alarm menu
F10Last 10 faults
FAnContinuous fan
gH1Gas heat, low stage
gH2Gas heat, high stage
IdLIdle - no call
L6FStored faults (view and clear)
rFdReset to factory defaults

Daikin General error codes

CodeMeaning
1Stage 1 heating active
1 2Stage 2 heating active
1 long beepOperation ended
1 short beepSetting changed
2 quick beepsOperation started
2 short beepsFilter replacement reset confirmed
3 long beepsWater tank empty during humidifying
3 short beepsUnit not usable
All 3 MODE lamps blink simultaneouslyAll MODE lamps blinking together
All 4 FAN lamps blink simultaneouslyAll FAN lamps blinking together
Dust/particle lamp blue, orange, redDust and particle level indication
Dust/particle sensor lamp remains orange or redDust/particle sensor lamp stays orange or red
Dust lamp blinks (green)Green dust lamp blinking
Filter lamp (orange) steadyDust collection filter nearing replacement
Filter lamp blinkingDust collection filter replacement due
Filter replacement lamp (orange) blinkingDust collection filter due for replacement
Filter replacement lamp blinksDust collection filter must be replaced
Filter replacement lamp lights upDust collection filter due soon
LOCK lamp (orange) litButton lock active
Odor lamp blinking with 3 long beepsCarbon filter unit or carbon filter not seated
Odor sensor lamp blinkingCarbon filter or filter fixing unit not installed correctly
Odor sensor lamp blinksOdor sensor lamp blinking
Odor sensor lamp blue, orange, redOdor level indication
PWR LED flashing greenPower wires reversed
UV ON/OFF lamp blinksUV ON/OFF lamp blinking
– –Humidity reading not ready

Daikin Heat Pump error codes

CodeMeaning
11Error 11: system test not completed
14Repeated high pressure faults (minor)
16Repeated low pressure faults (minor)
33Outdoor control board overheating (minor)
52Repeated compressor faults (minor)
53Repeated outdoor fan / board faults (minor)
54Repeated low discharge superheat faults (minor)
55Repeated high discharge temperature faults (minor)
57Sweating on the board cooling loop
76Indoor-outdoor, gas furnace or blower communication error (during operation)
77Indoor unit - thermostat communication error (start-up and during operation)
78Indoor unit - outdoor unit, gas furnace or blower unit communication error (startup operation)
A6Indoor fan motor (DC motor) abnormality
C4Indoor heat exchanger thermistor abnormality
C9Room temperature sensor / humidity sensor abnormality (communication or malfunction)
CCHumidity sensor abnormality (communication or malfunction)
CoreSense 1CoreSense: yellow 1 flash, long run time
CoreSense 2CoreSense: 2 flashes, pressure trip (yellow alert / red lock)
CoreSense 3CoreSense: 3 flashes, short cycling (yellow alert / red lock)
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)
CoreSense 5CoreSense: 5 flashes, moderate run trip (yellow alert / red lock)
CoreSense 9CoreSense: red 9 flashes, PROT terminal over current
CoreSense solid redCoreSense: solid red TRIP
CoreSense solid yellowCoreSense: solid yellow RUN
CoreSense TRIP+ALERT flashingCoreSense: TRIP and ALERT flashing together
E11System start-up test not done
E12Control board memory error
E13Repeated high pressure faults (critical)
E15Repeated low pressure faults (critical)
E17Repeated compressor faults (critical)
E18Control board may need replacing (outdoor fan drive)
E19Repeated outdoor fan / board faults (critical)
E20Outdoor EEV fault
E21Repeated low discharge superheat faults
E22Repeated high discharge temperature faults
E23Discharge temperature sensor out of range
E24High pressure switch open
E25Outdoor air temperature sensor open or shorted
E26Pressure sensor not responding
E27Outdoor coil defrost sensor out of range
E28Outdoor coil temperature sensor out of range
E29Liquid temperature sensor out of range
E30Control board may need replacing
E32Outdoor control board overheating (critical)
E34High current detected
E35High current, possible short circuit
E36Abnormal start-up
E37Control board may need replacing (fan motor link)
E38Compressor voltage problem
E39Control board may need replacing (thermistor input)
E40Compressor setup does not match the unit
E41Low refrigerant
E42Low supply voltage
E43High supply voltage
E44Outdoor temperature out of operating range
E47System verification test blocked by indoor heat
E49Charging mode blocked by indoor heat
E50Voltage problem on the control board
E51Communication problem seen by the outdoor board
E56Suction temperature sensor out of range
E57Sweating on the cooling loop (3.5 to 5.0 ton only)
E58Compressor overload (OL) sensor open
Eb0Indoor airflow near zero
Eb9Indoor airflow below what is needed
Ed0No shared data on the control
Ed1Bad shared or network data
Ed2Airflow needed is more than the indoor unit can give
Ed3Shared data does not match the hardware
Ed4Memory card data rejected
F6High pressure control in cooling
F8Compressor temperature abnormality (discharge pipe)
Green LED: 1 steady flashGreen LED steady flash, no network found
Green LED: OffGreen receive LED off
Green LED: Rapid flashingGreen LED rapid flashing, normal network traffic
Green LED: Solid onGreen LED solid, terminal 1 / terminal 2 miswire
Green Rx LED 1 steady flashNetwork: no network found
Green Rx LED offNetwork: no power or no communication
Green Rx LED on solidNetwork: terminal 1 / 2 miswired
H0Compressor system sensor abnormality
H6Position sensor abnormality (compressor start-up failure)
H8DC voltage/current sensor abnormality
Red comm LED 1 flashNetwork: communications failure
Red comm LED 2 flashesNetwork: out-of-box reset
Red LED: 1 flashRed LED 1 flash, communications failure
Red LED: 2 flashRed LED 2 flash, out-of-box reset
Red LED: OffRed communications LED off
U0Refrigerant shortage
U2Low-voltage or over-voltage detection

Daikin Mini-Split error codes

CodeMeaning
00Normal (no fault stored)
A1Indoor PCB abnormality
A5Freeze-up protection or heating peak-cut
A6Indoor fan motor (DC) abnormality
C4Indoor coil thermistor fault
C9Room temperature thermistor fault
CCFaulty humidity sensor
E1Outdoor PCB abnormality
E3High pressure switch tripped
E5Compressor overload (OL) tripped
E6Compressor lock
E7Outdoor DC fan lock
E8Input overcurrent
EAFour way valve abnormality
F3Discharge pipe temperature too high
F6High pressure control in cooling
F8Compressor temperature abnormality shutdown
H0Compressor current sensor abnormality
H6Compressor position sensor abnormality (start failure)
H8Current transformer (CT) abnormality
H9Outdoor air thermistor fault
J3Discharge pipe thermistor fault
J6Outdoor coil thermistor fault
J8Faulty liquid pipe temperature sensor
L3Electrical box temperature rise
L4Radiation fin temperature rise
L5Output overcurrent
P4Radiation fin thermistor fault
U0Refrigerant shortage
U2Low or high supply voltage detected
U4Indoor to outdoor signal error
U7Outdoor PCB internal communication error
UAIndoor and outdoor unit mismatch

Daikin Water Heater error codes

CodeMeaning
42Connector X3A disconnected (cascade)
80Thermistor connector X17A disconnected (cascade)
81Thermistor connector X18A disconnected (cascade)
A6Water not flowing in cascade unit
E3E3 subcode 01: cascade unit HPS connector unplugged
E4E4 subcode 02: heat source unit low refrigerant or stop valve closed
E9E9 subcode 01: cascade unit X23A valve coil connector unplugged
ECLow tank water temperature
F3F3 subcode 01: cascade unit low refrigerant
H9H9 subcode 02: heat source X18A thermistor disconnected
HJFlow rate cannot be adjusted (cascade)
J3J3 subcodes 16 to 19: cascade unit X29A thermistor disconnected
J5J5 subcode 03: heat source X30A thermistor disconnected
J6J6 subcode 02
J7J7 subcodes 13 and 14: cascade unit X30A thermistor disconnected
J8J8 subcode 02
J9J9 subcode 02
JAHigh pressure sensor connector X32A disconnected
JCLow pressure sensor connector X31A disconnected
LCInverter communication connectors disconnected
P1Power supply voltage imbalance
U1Power wiring reverse phase or no power
U2Power supply voltage error, imbalance or phase loss
UCUC: duplicate cascade unit address
UETransmission to tank control board not established
UFIncorrect water piping connection
UJActive filter error

Find codes by Daikin model

Daikin R-32 DC3S/DC4S/DC5S

DC3SQN**10AADC4SEA**10AADC4SQA**10AADC5SEA**10AA

Daikin FIT DC6VS/DC9VSA

DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810

Daikin DR96TN/DD96TN

DD96TN0403BNDD96TN0603BNDD96TN0803BNDD96TN1005CNDR96TN0303ANDR96TN0403ANDR96TN0603ANDR96TN0603BNDR96TN0803BNDR96TN0804CNDR96TN1004CNDR96TN1005CNDR96TN1205DN

Daikin R-32 DH4S/DH5S

DH4SEA**10AADH4SQA**10AADH5SEA**10AA

Daikin FIT DH6VS/DH7VSA

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Daikin FTX-W

FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9

Daikin troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977