Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code Green Rx LED on solid: Network: terminal 1 / 2 miswired (AC)

Updated · by Aurora Star Tech Inc.

Daikin error code Green Rx LED on solid on a air conditioner means: Network: terminal 1 / 2 miswired. It is also called Daikin diagnostic code Green Rx LED on solid.

Medium severityAir ConditionerAlso Heat PumpDaikin FIT DC6VS/DC9VSA

Homeowner? What Daikin code Green Rx LED on solid means for you

Check, then call Your air conditioner is reporting: Network: terminal 1 / 2 miswired. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code Green Rx LED on solid mean?

Green receive LED stays on solid.

Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code Green Rx LED on solid

  • Terminal 1 and 2 swapped at the indoor unit, thermostat or outdoor unit
  • Short between terminal 1 and 2
  • Terminal 1 or 2 shorted to C or R (24 VAC)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code Green Rx LED on solid

DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810

Other Daikin AC codes

CodeMeaning
Ed1Bad shared or network data
Ed2Airflow needed is more than the indoor unit can give
Ed3Shared data does not match the hardware
Ed4Memory card data rejected
Green Rx LED 1 steady flashNetwork: no network found
Green Rx LED offNetwork: no power or no communication
Red comm LED 1 flashNetwork: communications failure
Red comm LED 2 flashesNetwork: out-of-box reset

All Daikin Air Conditioner error codes →

Daikin code Green Rx LED on solid: homeowner questions

What does Daikin code Green Rx LED on solid mean?

Network: terminal 1 / 2 miswired. Green receive LED stays on solid.

Is it safe to keep using my air conditioner with code Green Rx LED on solid?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code Green Rx LED on solid myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code Green Rx LED on solid comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code Green Rx LED on solid near me?

Aurora Star Tech Inc. repairs Daikin air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit installation & service reference, Network Troubleshooting p.47 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service