Daikin Error Code E77: No thermostat communication (Air Handler)
Daikin error code E77 on a air handler means: No thermostat communication. It is also called Daikin diagnostic code E77.
Homeowner? What Daikin code E77 means for you
Check, then call Your air handler is reporting: No thermostat communication. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code E77 mean?
The EEV indoor unit has no communication with the thermostat. Shown on the EEV indoor unit display.
Applies to: EEV indoor units (air handlers and cased coils)
Common causes of Daikin code E77
- Broken thermostat communication wires
- Faulty thermostat
Other Daikin Air Handler codes
All Daikin Air Handler error codes →
Daikin code E77: homeowner questions
What does Daikin code E77 mean?
No thermostat communication. The EEV indoor unit has no communication with the thermostat. Shown on the EEV indoor unit display.
Is it safe to keep using my air handler with code E77?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Daikin code E77 myself?
You can try one reset (power off for 30 seconds, then on). If Daikin code E77 comes back, the cause is still there and a licensed technician should check it.
Who can fix Daikin code E77 near me?
Aurora Star Tech Inc. repairs Daikin air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Air filter replacement and service interval All brands · Air Handler
- Cold-weather freeze protection when system is off All brands · Air Handler
- Condensate drain check All brands · Air Handler
- Disconnect power before opening access panels All brands · Air Handler
- Indoor humidity above 60% RH All brands · Air Handler
- Insufficient heating or cooling All brands · Air Handler
- No heating or cooling, blower does not run All brands · Air Handler
- System fails to operate All brands · Air Handler
Source: Daikin SiUS612209EB service instructions, p. 32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.