Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code U0: Refrigerant shortage (Mini-Split)

Updated · by Aurora Star Tech Inc.

Daikin error code U0 on a mini-split means: Refrigerant shortage. It is also called Daikin diagnostic code U0.

High severityMini-SplitDaikin FTX-W

Homeowner? What Daikin code U0 means for you

Call a technician Your ductless mini-split is reporting: Refrigerant shortage. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code U0 mean?

Shows only when the system shuts down. The manual lists it but gives no check procedure in the pages covered.

Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9

Common causes of Daikin code U0

  • Low refrigerant charge
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code U0

FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9

Other Daikin Mini-Split codes

CodeMeaning
J3Discharge pipe thermistor fault
J6Outdoor coil thermistor fault
L3Electrical box temperature rise
L4Radiation fin temperature rise
L5Output overcurrent
P4Radiation fin thermistor fault
U2Low or high supply voltage detected
U4Indoor to outdoor signal error
U7Outdoor PCB internal communication error
UAIndoor and outdoor unit mismatch

All Daikin Mini-Split error codes →

Daikin code U0: homeowner questions

What does Daikin code U0 mean?

Refrigerant shortage. Shows only when the system shuts down. The manual lists it but gives no check procedure in the pages covered.

Is it safe to keep using my ductless mini-split with code U0?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code U0 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code U0 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code U0 near me?

Aurora Star Tech Inc. repairs Daikin ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin FTX-W service manual SiUS042228E, Error code list 4.1, p.68. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service