Daikin Error Code A6: Indoor fan motor (DC motor) abnormality (Heat Pump)
Daikin error code A6 on a heat pump means: Indoor fan motor (DC motor) abnormality. It is also called Daikin diagnostic code A6.
Homeowner? What Daikin code A6 means for you
Check, then call Your heat pump is reporting: Indoor fan motor (DC motor) abnormality. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code A6 mean?
The control board monitors indoor fan speed. The fault is set when the fan does not reach the demanded speed for the selected tap and runs below 50% of its maximum speed, or when the fan does not turn for more than 5 seconds after starting.
Applies to: FTXM-W/V wall mounted inverter heat pump, indoor unit
Common causes of Daikin code A6
- Large drop in power supply voltage
- Short between turns inside the fan motor winding
- Broken wire inside the fan motor
A technician checks these and 3 other possible causes on site before replacing any part.
Other Daikin Heat Pump codes
All Daikin Heat Pump error codes →
Daikin code A6: homeowner questions
What does Daikin code A6 mean?
Indoor fan motor (DC motor) abnormality. The control board monitors indoor fan speed. The fault is set when the fan does not reach the demanded speed for the selected tap and runs below 50% of its maximum speed, or when the fan does not turn for more than 5 seconds after starting.
Is it safe to keep using my heat pump with code A6?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Daikin code A6 myself?
You can try one reset (power off for 30 seconds, then on). If Daikin code A6 comes back, the cause is still there and a licensed technician should check it.
Who can fix Daikin code A6 near me?
Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: SiUS042113EA service manual, p. 105-106. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.