Daikin Error Code E57: Sweating on the cooling loop (3.5 to 5.0 ton only) (Heat Pump)
Daikin error code E57 on a heat pump means: Sweating on the cooling loop (3.5 to 5.0 ton only). It is also called Daikin diagnostic code E57.
Homeowner? What Daikin code E57 means for you
Check, then call Your heat pump is reporting: Sweating on the cooling loop (3.5 to 5.0 ton only). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code E57 mean?
The control senses sweating on the cooling loop. This code may not show on the thermostat, so check the outdoor unit error history.
Applies to: DX6VS/DZ6VS outdoor unit, 3.5 to 5.0 ton
Common causes of Daikin code E57
- Refrigerant leak
- Low refrigerant charge
- Faulty indoor EEV or indoor EEV coil
A technician checks these and 1 other possible causes on site before replacing any part.
Other Daikin Heat Pump codes
All Daikin Heat Pump error codes →
Daikin code E57: homeowner questions
What does Daikin code E57 mean?
Sweating on the cooling loop (3.5 to 5.0 ton only). The control senses sweating on the cooling loop. This code may not show on the thermostat, so check the outdoor unit error history.
Is it safe to keep using my heat pump with code E57?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Daikin code E57 myself?
You can try one reset (power off for 30 seconds, then on). If Daikin code E57 comes back, the cause is still there and a licensed technician should check it.
Who can fix Daikin code E57 near me?
Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: SiUS612209EA service instructions, p. 47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.