Daikin Error Code E6: Compressor lock (Mini-Split)
Daikin error code E6 on a mini-split means: Compressor lock. It is also called Daikin diagnostic code E6.
Homeowner? What Daikin code E6 means for you
Stop and call Your ductless mini-split is reporting: Compressor lock. This code is a safety shutdown. Turn the ductless mini-split off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
- Check the breaker and the outdoor disconnect; both should be ON.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code E6 mean?
A lock is detected from the current waveform when high frequency voltage is applied to the motor. Repeats lead to shutdown. Resets after about 11 minutes of error-free running. Shows only on system shutdown.
Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9
Common causes of Daikin code E6
- Closed stop valve
- Locked compressor
- Compressor harness disconnected
Daikin models that use code E6
FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9
Other Daikin Mini-Split codes
All Daikin Mini-Split error codes →
Daikin code E6: homeowner questions
What does Daikin code E6 mean?
Compressor lock. A lock is detected from the current waveform when high frequency voltage is applied to the motor. Repeats lead to shutdown. Resets after about 11 minutes of error-free running. Shows only on system shutdown.
Is it safe to keep using my ductless mini-split with code E6?
No. Code E6 is a safety shutdown, so keep the ductless mini-split off until a licensed technician has checked it.
Can I reset Daikin code E6 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Daikin code E6 near me?
Aurora Star Tech Inc. repairs Daikin ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Indoor unit leaking water All brands · Mini-Split
- Poor capacity / high head All brands · Mini-Split
- Water leaking All brands · Mini-Split
- Check compressor and inverter with the analyzer Daikin · Mini-Split
- Check expansion valve Daikin · Mini-Split
- Check outdoor fan motor Daikin · Mini-Split
- Check power module and diode bridge for shorts Daikin · Mini-Split
- Check thermistors by resistance Daikin · Mini-Split
- Force cooling for testing Daikin · Mini-Split
- Indoor operation lamp blinking every 0.5 seconds Daikin · Mini-Split
- Loud noise or vibration from outdoor unit Daikin · Mini-Split
- Outdoor LED A not blinking Daikin · Mini-Split
- Pump down before moving or scrapping the unit Daikin · Mini-Split
- Read fault codes from the remote, method 1 Daikin · Mini-Split
- Read fault codes from the remote, method 2 Daikin · Mini-Split
- Runs but does not cool or heat Daikin · Mini-Split
- Unit does not run at all Daikin · Mini-Split
- Unit stops now and then Daikin · Mini-Split
Source: Daikin FTX-W service manual SiUS042228E, Troubleshooting 4.13, p.87. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.