Daikin Error Code E35: High current, possible short circuit (Heat Pump)
Daikin error code E35 on a heat pump means: High current, possible short circuit. It is also called Daikin diagnostic code E35.
Homeowner? What Daikin code E35 means for you
Stop and call Your heat pump is reporting: High current, possible short circuit. This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code E35 mean?
Thermostat shows 35, outdoor board display shows E35. The control board saw high current that points to a possible short.
Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)
Common causes of Daikin code E35
- Short circuit
- Stop valve not fully open
- Too much refrigerant
A technician checks these and 2 other possible causes on site before replacing any part.
Daikin models that use code E35
DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810
Other Daikin Heat Pump codes
All Daikin Heat Pump error codes →
Daikin code E35: homeowner questions
What does Daikin code E35 mean?
High current, possible short circuit. Thermostat shows 35, outdoor board display shows E35. The control board saw high current that points to a possible short.
Is it safe to keep using my heat pump with code E35?
No. Code E35 is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.
Can I reset Daikin code E35 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Daikin code E35 near me?
Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
- Odour at registers (dirty sock) All brands · Heat Pump
- Poor heating but OK cooling (or vice-versa) All brands · Heat Pump
- Service problem analysis (Amana chart excerpt) All brands · Heat Pump
- Subcooling too high All brands · Heat Pump
- Subcooling too low vs mfr target All brands · Heat Pump
- TXV bulb/diaphragm failure All brands · Heat Pump
- Water-source: coil freezing All brands · Heat Pump
- Won't change mode / both coils same temperature All brands · Heat Pump
- Wrong superheat after line-set change; poor capacity All brands · Heat Pump
- FIT communication error: network check Daikin · Heat Pump
- FIT: reading the fault code and fault history Daikin · Heat Pump
- No cooling: heat pump (1 stage) check order Daikin · Heat Pump
- No heat: heat pump (1 stage) check order Daikin · Heat Pump
- Reversing valve will not shift Daikin · Heat Pump
- Testing the run capacitor Daikin · Heat Pump
Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.