Daikin Error Code E35: High current, possible short circuit (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code E35 on a heat pump means: High current, possible short circuit. It is also called Daikin diagnostic code E35.

Critical severityHeat PumpDaikin FIT DH6VS/DH7VSA

Homeowner? What Daikin code E35 means for you

Stop and call Your heat pump is reporting: High current, possible short circuit. This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code E35 mean?

Thermostat shows 35, outdoor board display shows E35. The control board saw high current that points to a possible short.

Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code E35

  • Short circuit
  • Stop valve not fully open
  • Too much refrigerant

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code E35

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Other Daikin Heat Pump codes

CodeMeaning
E27Outdoor coil defrost sensor out of range
E28Outdoor coil temperature sensor out of range
E29Liquid temperature sensor out of range
E30Control board may need replacing
E32Outdoor control board overheating (critical)
E34High current detected
E36Abnormal start-up
E37Control board may need replacing (fan motor link)
E38Compressor voltage problem
E39Control board may need replacing (thermistor input)
E40Compressor setup does not match the unit
E41Low refrigerant

All Daikin Heat Pump error codes →

Daikin code E35: homeowner questions

What does Daikin code E35 mean?

High current, possible short circuit. Thermostat shows 35, outdoor board display shows E35. The control board saw high current that points to a possible short.

Is it safe to keep using my heat pump with code E35?

No. Code E35 is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.

Can I reset Daikin code E35 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Daikin code E35 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service