Daikin Error Code C4: Indoor coil thermistor fault (Mini-Split)
Daikin error code C4 on a mini-split means: Indoor coil thermistor fault. It is also called Daikin diagnostic code C4.
Homeowner? What Daikin code C4 means for you
Check, then call Your ductless mini-split is reporting: Indoor coil thermistor fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
- Check the breaker and the outdoor disconnect; both should be ON.
- Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
- Keep the outdoor unit clear of snow, ice and leaves.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code C4 mean?
The indoor heat exchanger thermistor input reads 4.96 V or more, or 0.04 V or less, with power on (open or shorted sensor).
Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9
Common causes of Daikin code C4
- Connector not seated
- Faulty thermistor
- Faulty indoor PCB
Daikin models that use code C4
FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9
Other Daikin Mini-Split codes
All Daikin Mini-Split error codes →
Daikin code C4: homeowner questions
What does Daikin code C4 mean?
Indoor coil thermistor fault. The indoor heat exchanger thermistor input reads 4.96 V or more, or 0.04 V or less, with power on (open or shorted sensor).
Is it safe to keep using my ductless mini-split with code C4?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Daikin code C4 myself?
You can try one reset (power off for 30 seconds, then on). If Daikin code C4 comes back, the cause is still there and a licensed technician should check it.
Who can fix Daikin code C4 near me?
Aurora Star Tech Inc. repairs Daikin ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Indoor unit leaking water All brands · Mini-Split
- Poor capacity / high head All brands · Mini-Split
- Water leaking All brands · Mini-Split
- Check compressor and inverter with the analyzer Daikin · Mini-Split
- Check expansion valve Daikin · Mini-Split
- Check outdoor fan motor Daikin · Mini-Split
- Check power module and diode bridge for shorts Daikin · Mini-Split
- Check thermistors by resistance Daikin · Mini-Split
- Force cooling for testing Daikin · Mini-Split
- Indoor operation lamp blinking every 0.5 seconds Daikin · Mini-Split
- Loud noise or vibration from outdoor unit Daikin · Mini-Split
- Outdoor LED A not blinking Daikin · Mini-Split
- Pump down before moving or scrapping the unit Daikin · Mini-Split
- Read fault codes from the remote, method 1 Daikin · Mini-Split
- Read fault codes from the remote, method 2 Daikin · Mini-Split
- Runs but does not cool or heat Daikin · Mini-Split
- Unit does not run at all Daikin · Mini-Split
- Unit stops now and then Daikin · Mini-Split
Source: Daikin FTX-W service manual SiUS042228E, Troubleshooting 4.5, p.75. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.