Daikin Error Code 11: Error 11: system test not completed (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code 11 on a heat pump means: Error 11: system test not completed. It is also called Daikin diagnostic code 11.

Medium severityHeat PumpDaikin One Touch

Homeowner? What Daikin code 11 means for you

Check, then call Your heat pump is reporting: Error 11: system test not completed. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code 11 mean?

Error code 11 is generated when the required system test has not been completed on an inverter system. The code clears once the test is complete.

Applies to: Inverter systems using Daikin One Touch

Common causes of Daikin code 11

  • System test has not been run on an inverter system.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Heat Pump codes

CodeMeaning
14Repeated high pressure faults (minor)
16Repeated low pressure faults (minor)
33Outdoor control board overheating (minor)
52Repeated compressor faults (minor)
53Repeated outdoor fan / board faults (minor)
54Repeated low discharge superheat faults (minor)
55Repeated high discharge temperature faults (minor)
57Sweating on the board cooling loop
76Indoor-outdoor, gas furnace or blower communication error (during operation)
77Indoor unit - thermostat communication error (start-up and during operation)
78Indoor unit - outdoor unit, gas furnace or blower unit communication error (startup operation)
A6Indoor fan motor (DC motor) abnormality

All Daikin Heat Pump error codes →

Daikin code 11: homeowner questions

What does Daikin code 11 mean?

Error 11: system test not completed. Error code 11 is generated when the required system test has not been completed on an inverter system. The code clears once the test is complete.

Is it safe to keep using my heat pump with code 11?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code 11 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code 11 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code 11 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin One Touch Smart Thermostat Training Module TRC-10, p. 30. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977