Daikin Error Code U2: Low or high supply voltage detected (Mini-Split)

Updated · by Aurora Star Tech Inc.

Daikin error code U2 on a mini-split means: Low or high supply voltage detected. It is also called Daikin diagnostic code U2.

High severityMini-SplitDaikin FTX-W

Homeowner? What Daikin code U2 means for you

Call a technician Your ductless mini-split is reporting: Low or high supply voltage detected. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code U2 mean?

Indoor PCB flags it when it sees no zero-cross signal for about 10 seconds. Outdoor PCB flags it when DC bus voltage drops below roughly 150 to 200 V or an over-voltage signal is raised. The compressor stops and restarts after a 3 minute wait.

Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9

Common causes of Daikin code U2

  • Supply voltage out of spec
  • Momentary voltage drop or power failure
  • Electrical noise

A technician checks these and 5 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code U2

FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9

Other Daikin Mini-Split codes

CodeMeaning
J6Outdoor coil thermistor fault
L3Electrical box temperature rise
L4Radiation fin temperature rise
L5Output overcurrent
P4Radiation fin thermistor fault
U0Refrigerant shortage
U4Indoor to outdoor signal error
U7Outdoor PCB internal communication error
UAIndoor and outdoor unit mismatch

All Daikin Mini-Split error codes →

Daikin code U2: homeowner questions

What does Daikin code U2 mean?

Low or high supply voltage detected. Indoor PCB flags it when it sees no zero-cross signal for about 10 seconds. Outdoor PCB flags it when DC bus voltage drops below roughly 150 to 200 V or an over-voltage signal is raised. The compressor stops and restarts after a 3 minute…

Is it safe to keep using my ductless mini-split with code U2?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code U2 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code U2 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code U2 near me?

Aurora Star Tech Inc. repairs Daikin ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin FTX-W service manual SiUS042228E, Troubleshooting 4.6, p.76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977