Daikin Error Code EEC: Internal gas valve error – valve energized when it should not be (Furnace)
Daikin error code EEC on a furnace means: Internal gas valve error - valve energized when it should not be. It is also called Daikin diagnostic code EEC.
Homeowner? What Daikin code EEC means for you
Stop and call Your furnace is reporting: Internal gas valve error - valve energized when it should not be. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code EEC mean?
The control sees voltage at the gas valve with no call for heat. Flowcharts call this code EC. Note: the wiring diagram legend labels this code 'External Gas Valve Error' while the troubleshooting chart and flowchart say internal - follow the chart.
Applies to: Daikin DR96TN (upflow/horizontal) and DD96TN (downflow/horizontal) two-stage 96% furnaces with 9-speed ECM motor, R-32 ready
Common causes of Daikin code EEC
- Gas valve relay on the control board stuck closed
- Miswiring that feeds the gas valve circuit
- Gas valve shorted to ground or loose connection
Daikin models that use code EEC
DD96TN0403BNDD96TN0603BNDD96TN0803BNDD96TN1005CNDR96TN0303ANDR96TN0403ANDR96TN0603ANDR96TN0603BNDR96TN0803BNDR96TN0804CNDR96TN1004CNDR96TN1005CNDR96TN1205DN
Other Daikin Furnace codes
All Daikin Furnace error codes →
Daikin code EEC: homeowner questions
What does Daikin code EEC mean?
Internal gas valve error - valve energized when it should not be. The control sees voltage at the gas valve with no call for heat. Flowcharts call this code EC. Note: the wiring diagram legend labels this code 'External Gas Valve Error' while the troubleshooting chart and flowchart say internal - follow…
Is it safe to keep using my furnace with code EEC?
No. Code EEC is a safety shutdown, so keep the furnace off until a licensed technician has checked it.
Can I reset Daikin code EEC myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Daikin code EEC near me?
Aurora Star Tech Inc. repairs Daikin furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: Daikin RSD6612304 (DR96TN/DD96TN service), 2 Stage Troubleshooting Codes, p.28-29; Error Code (Eb & EC) flowchart p.37; wiring diagram legend p.38. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.