Daikin Error Code 57: Sweating on the board cooling loop (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code 57 on a heat pump means: Sweating on the board cooling loop. It is also called Daikin diagnostic code 57.

Medium severityHeat PumpDaikin FIT DH6VS/DH7VSA

Homeowner? What Daikin code 57 means for you

Check, then call Your heat pump is reporting: Sweating on the board cooling loop. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code 57 mean?

The thermostat shows 57; the board shows nothing. The control senses condensation on the refrigerant cooling loop of the board (3.5-5.0 ton FIT and 3.0-4.0 ton Enhanced Capacity/High Efficiency FIT only).

Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code 57

  • Refrigerant leak
  • Low charge
  • Bad indoor EEV or its coil

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code 57

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Other Daikin Heat Pump codes

CodeMeaning
16Repeated low pressure faults (minor)
33Outdoor control board overheating (minor)
52Repeated compressor faults (minor)
53Repeated outdoor fan / board faults (minor)
54Repeated low discharge superheat faults (minor)
55Repeated high discharge temperature faults (minor)
CoreSense 1CoreSense: yellow 1 flash, long run time
CoreSense 2CoreSense: 2 flashes, pressure trip (yellow alert / red lock)
CoreSense 3CoreSense: 3 flashes, short cycling (yellow alert / red lock)
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)
CoreSense 5CoreSense: 5 flashes, moderate run trip (yellow alert / red lock)
CoreSense 9CoreSense: red 9 flashes, PROT terminal over current

All Daikin Heat Pump error codes →

Daikin code 57: homeowner questions

What does Daikin code 57 mean?

Sweating on the board cooling loop. The thermostat shows 57; the board shows nothing. The control senses condensation on the refrigerant cooling loop of the board (3.5-5.0 ton FIT and 3.0-4.0 ton Enhanced Capacity/High Efficiency FIT only).

Is it safe to keep using my heat pump with code 57?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code 57 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code 57 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code 57 near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.45 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.