Daikin Air Conditioner: Cooling analysis: possible causes and remedies

Updated · by Aurora Star Tech Inc.

Cooling analysis: possible causes and remedies on a Daikin air conditioner: Use the cooling analysis chart when readings fall outside the listed thresholds. Marked symptoms show which causes to check.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DX6VS/DZ6VS outdoor units in cooling

Common causes of cooling analysis: possible causes and remedies

  • Liquid or gas stop valve not fully open
  • Line set restriction or line set too long
  • Blocked filter-dryer
  • Indoor EEV coil or EEV failure
  • Outdoor solenoid valve coil or valve failure
  • High pressure switch failure
  • Pressure sensor failure
  • Outdoor suction, discharge, coil or air thermistor failure
  • Outdoor or indoor air recirculation
  • Dirty outdoor or indoor heat exchanger
  • Outdoor or indoor ambient/return air temperature out of range
  • Non-condensable gas in system
  • Outdoor fan motor failure
  • Overcharge or undercharge of refrigerant; leak
  • Outdoor control board failure; indoor unit failure
  • Compressor failure
  • Low indoor CFM

How to fix cooling analysis: possible causes and remedies: step by step

  1. Fully open the liquid stop valve and gas stop valve.
  2. Check the line set for restrictions and length; change outdoor position if needed.
  3. Replace the filter-dryer if blocked.
  4. Check indoor and outdoor EEV coil connections and EEV operation; repair or replace as needed.
  5. Check the outdoor solenoid valve coil and valve; repair or replace as needed.
  6. Check high pressure switch resistance; replace if needed.
  7. Check pressure sensor resistance and connections; replace if needed.
  8. Check thermistor resistance and connections; replace if needed.
  9. Re-arrange outdoor or indoor unit position to stop recirculation.
  10. Clean outdoor or indoor heat exchanger.
  11. Recover refrigerant, evacuate the pipe and recharge if non-condensable gas is present.
  12. Replace outdoor fan motor if failed.
  13. Recover part of charge if overcharged; test for leaks and add refrigerant if undercharged.
  14. Find and repair the leak point.
  15. Replace outdoor control board if failed; replace indoor unit or compressor if failed.
  16. Check airflow trim and indoor fan motor; repair or replace as needed.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Air Conditioner codes

Source: Daikin SiUS612209EB service instructions, p. 12. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.