Daikin Error Code L3: Electrical box temperature rise (Mini-Split)

Updated · by Aurora Star Tech Inc.

Daikin error code L3 on a mini-split means: Electrical box temperature rise. It is also called Daikin diagnostic code L3.

Medium severityMini-SplitDaikin FTX-W

Homeowner? What Daikin code L3 means for you

Check, then call Your ductless mini-split is reporting: Electrical box temperature rise. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code L3 mean?

With the compressor off, radiation fin temperature is above 92 C (197.6 F). Clears below 70 C (158 F). The outdoor fan runs to cool the board above 77 C (170.6 F) and stops below 70 C.

Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9

Common causes of Daikin code L3

  • Faulty outdoor fan motor
  • Blocked airflow or short cycling
  • Faulty fin thermistor

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code L3

FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9

Other Daikin Mini-Split codes

CodeMeaning
H0Compressor current sensor abnormality
H6Compressor position sensor abnormality (start failure)
H8Current transformer (CT) abnormality
H9Outdoor air thermistor fault
J3Discharge pipe thermistor fault
J6Outdoor coil thermistor fault
L4Radiation fin temperature rise
L5Output overcurrent
P4Radiation fin thermistor fault
U0Refrigerant shortage
U2Low or high supply voltage detected
U4Indoor to outdoor signal error

All Daikin Mini-Split error codes →

Daikin code L3: homeowner questions

What does Daikin code L3 mean?

Electrical box temperature rise. With the compressor off, radiation fin temperature is above 92 C (197.6 F). Clears below 70 C (158 F). The outdoor fan runs to cool the board above 77 C (170.6 F) and stops below 70 C.

Is it safe to keep using my ductless mini-split with code L3?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code L3 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code L3 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code L3 near me?

Aurora Star Tech Inc. repairs Daikin ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin FTX-W service manual SiUS042228E, Troubleshooting 4.24, p.105. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.