Daikin Error Code 73: Liquid side thermistor abnormality (Air Handler)
Daikin error code 73 on a air handler means: Liquid side thermistor abnormality. It is also called Daikin diagnostic code 73.
Homeowner? What Daikin code 73 means for you
Check, then call Your air handler is reporting: Liquid side thermistor abnormality. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code 73 mean?
The liquid thermistor reads open or shorted, or its value is outside the normal range. Check at X15A, pins 4 and 5.
Applies to: EEV air handler, EEV cased coil
Common causes of Daikin code 73
- Open or short circuit of the liquid thermistor (X5A)
- Liquid thermistor reading incorrect or outside normal range
- Indoor (ID) control board failure
Other Daikin Air Handler codes
All Daikin Air Handler error codes →
Daikin code 73: homeowner questions
What does Daikin code 73 mean?
Liquid side thermistor abnormality. The liquid thermistor reads open or shorted, or its value is outside the normal range. Check at X15A, pins 4 and 5.
Is it safe to keep using my air handler with code 73?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Daikin code 73 myself?
You can try one reset (power off for 30 seconds, then on). If Daikin code 73 comes back, the cause is still there and a licensed technician should check it.
Who can fix Daikin code 73 near me?
Aurora Star Tech Inc. repairs Daikin air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Air filter replacement and service interval All brands · Air Handler
- Cold-weather freeze protection when system is off All brands · Air Handler
- Condensate drain check All brands · Air Handler
- Disconnect power before opening access panels All brands · Air Handler
- Indoor humidity above 60% RH All brands · Air Handler
- Insufficient heating or cooling All brands · Air Handler
- No heating or cooling, blower does not run All brands · Air Handler
- System fails to operate All brands · Air Handler
Source: Daikin SiUS612209EA service instructions, p. 65. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.