Daikin Error Code Red LED: 2 flash: Red LED 2 flash, out-of-box reset (Heat Pump)
Daikin error code Red LED: 2 flash on a heat pump means: Red LED 2 flash, out-of-box reset. It is also called Daikin diagnostic code Red LED: 2 flash.
Homeowner? What Daikin code Red LED: 2 flash means for you
Usually minor Your heat pump is reporting: Red LED 2 flash, out-of-box reset. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code Red LED: 2 flash mean?
The control has reset out of the box, either from power-up or a learn button press.
Applies to: DX6VS/DZ6VS outdoor unit and indoor unit control boards
Common causes of Daikin code Red LED: 2 flash
- Control power up
- Learn button pressed
Other Daikin Heat Pump codes
All Daikin Heat Pump error codes →
Daikin code Red LED: 2 flash: homeowner questions
What does Daikin code Red LED: 2 flash mean?
Red LED 2 flash, out-of-box reset. The control has reset out of the box, either from power-up or a learn button press.
Is it safe to keep using my heat pump with code Red LED: 2 flash?
Usually yes. Code Red LED: 2 flash is normally minor, but if it keeps coming back have it checked.
Can I reset Daikin code Red LED: 2 flash myself?
You can try one reset (power off for 30 seconds, then on). If Daikin code Red LED: 2 flash comes back, the cause is still there and a licensed technician should check it.
Who can fix Daikin code Red LED: 2 flash near me?
Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Daikin DX6VS/DZ6VS outdoor unit installation manual, p. 47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.