Daikin Error Code U1: Power wiring reverse phase or no power (Water Heater)
Daikin error code U1 on a water heater means: Power wiring reverse phase or no power. It is also called Daikin diagnostic code U1.
Homeowner? What Daikin code U1 means for you
Stop and call Your heating or cooling system is reporting: Power wiring reverse phase or no power. This code is a safety shutdown. Turn the heating or cooling system off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code U1 mean?
Subdivisions 01 and 05: reverse phase (two of three phases exchanged). Subdivisions 04 and 06: no power supplied to the unit, including phase loss. 01 and 04 are cascade unit, 05 and 06 are heat source unit.
Applies to: Cascade unit and heat source unit
Common causes of Daikin code U1
- Two phases swapped (01, 05)
- No power or phase loss to unit (04, 06)
Other Daikin Water Heater codes
All Daikin Water Heater error codes →
Daikin code U1: homeowner questions
What does Daikin code U1 mean?
Power wiring reverse phase or no power. Subdivisions 01 and 05: reverse phase (two of three phases exchanged). Subdivisions 04 and 06: no power supplied to the unit, including phase loss. 01 and 04 are cascade unit, 05 and 06 are heat source unit.
Is it safe to keep using my heating or cooling system with code U1?
No. Code U1 is a safety shutdown, so keep the heating or cooling system off until a licensed technician has checked it.
Can I reset Daikin code U1 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Daikin code U1 near me?
Aurora Star Tech Inc. repairs Daikin heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Additional refrigerant charge threshold Daikin · Water Heater
- Cascade pump may run with no hot water demand Daikin · Water Heater
- Cascade unit power and transmission conduit entry Daikin · Water Heater
- Charge R410A as liquid only Daikin · Water Heater
- Check accessories before installing Daikin · Water Heater
- Check phase balance and phase rotation Daikin · Water Heater
- Choose a safe installation location Daikin · Water Heater
- Cold-weather shutdown: drain the cascade unit Daikin · Water Heater
Source: Daikin Mega-Q installation manual, p. 49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.