Daikin error code J6 on a mini-split means: Outdoor coil thermistor fault. It is also called Daikin diagnostic code J6.

Medium severityMini-SplitDaikin FTX-W

Homeowner? What Daikin code J6 means for you

Check, then call Your ductless mini-split is reporting: Outdoor coil thermistor fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code J6 mean?

The outdoor heat exchanger thermistor input reads 4.96 V or more, or 0.04 V or less, with power on.

Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9

Common causes of Daikin code J6

  • Connector not seated
  • Faulty thermistor
  • Faulty outdoor PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code J6

FTX30WVJU9FTX36WVJU9RK30WMVJU9RK36WMVJU9RX30WMVJU9RX36WMVJU9

Other Daikin Mini-Split codes

CodeMeaning
F8Compressor temperature abnormality shutdown
H0Compressor current sensor abnormality
H6Compressor position sensor abnormality (start failure)
H8Current transformer (CT) abnormality
H9Outdoor air thermistor fault
J3Discharge pipe thermistor fault
L3Electrical box temperature rise
L4Radiation fin temperature rise
L5Output overcurrent
P4Radiation fin thermistor fault
U0Refrigerant shortage
U2Low or high supply voltage detected

All Daikin Mini-Split error codes →

Daikin code J6: homeowner questions

What does Daikin code J6 mean?

Outdoor coil thermistor fault. The outdoor heat exchanger thermistor input reads 4.96 V or more, or 0.04 V or less, with power on.

Is it safe to keep using my ductless mini-split with code J6?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Daikin code J6 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code J6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code J6 near me?

Aurora Star Tech Inc. repairs Daikin ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin FTX-W service manual SiUS042228E, Troubleshooting 4.23, p.103. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977