Daikin Error Code UE: Transmission to tank control board not established (Water Heater)
Daikin error code UE on a water heater means: Transmission to tank control board not established. It is also called Daikin diagnostic code UE.
Homeowner? What Daikin code UE means for you
Call a technician Your heating or cooling system is reporting: Transmission to tank control board not established. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Daikin error code UE mean?
Controller kit: transmission between the cascade unit and the tank control board is not established. Also the cascade central address has not been set.
Applies to: Controller kit
Common causes of Daikin code UE
- Wiring between cascade unit and tank control board faulty
- Cascade central address not set
Other Daikin Water Heater codes
All Daikin Water Heater error codes →
Daikin code UE: homeowner questions
What does Daikin code UE mean?
Transmission to tank control board not established. Controller kit: transmission between the cascade unit and the tank control board is not established. Also the cascade central address has not been set.
Is it safe to keep using my heating or cooling system with code UE?
It depends on the cause. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Daikin code UE myself?
You can try one reset (power off for 30 seconds, then on). If Daikin code UE comes back, the cause is still there and a licensed technician should check it.
Who can fix Daikin code UE near me?
Aurora Star Tech Inc. repairs Daikin heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Additional refrigerant charge threshold Daikin · Water Heater
- Cascade pump may run with no hot water demand Daikin · Water Heater
- Cascade unit power and transmission conduit entry Daikin · Water Heater
- Charge R410A as liquid only Daikin · Water Heater
- Check accessories before installing Daikin · Water Heater
- Check phase balance and phase rotation Daikin · Water Heater
- Choose a safe installation location Daikin · Water Heater
- Cold-weather shutdown: drain the cascade unit Daikin · Water Heater
Source: Daikin Mega-Q installation manual, p. 50. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.