Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code Green LED: Solid on: Green LED solid, terminal 1 / terminal 2 miswire (Heat Pump)

Updated · by Aurora Star Tech Inc.

Daikin error code Green LED: Solid on on a heat pump means: Green LED solid, terminal 1 / terminal 2 miswire. It is also called Daikin diagnostic code Green LED: Solid on.

High severityHeat PumpDX6VS · DZ6VS

Homeowner? What Daikin code Green LED: Solid on means for you

Call a technician Your heat pump is reporting: Green LED solid, terminal 1 / terminal 2 miswire. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code Green LED: Solid on mean?

Terminal 1 and terminal 2 are reversed, shorted, or shorted to terminal C or R.

Applies to: DX6VS/DZ6VS outdoor unit and indoor unit control boards

Common causes of Daikin code Green LED: Solid on

  • Terminal 1 and terminal 2 wires reversed at indoor unit, thermostat, or outdoor unit
  • Short between terminal 1 and terminal 2
  • Short between terminal 1 or 2 and terminal C (24VAC) or terminal R (24VAC, COM)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Heat Pump codes

CodeMeaning
Ed4Memory card data rejected
F6High pressure control in cooling
F8Compressor temperature abnormality (discharge pipe)
Green LED: 1 steady flashGreen LED steady flash, no network found
Green LED: OffGreen receive LED off
Green LED: Rapid flashingGreen LED rapid flashing, normal network traffic
Green Rx LED 1 steady flashNetwork: no network found
Green Rx LED offNetwork: no power or no communication
Green Rx LED on solidNetwork: terminal 1 / 2 miswired
H0Compressor system sensor abnormality
H6Position sensor abnormality (compressor start-up failure)
H8DC voltage/current sensor abnormality

All Daikin Heat Pump error codes →

Daikin code Green LED: Solid on: homeowner questions

What does Daikin code Green LED: Solid on mean?

Green LED solid, terminal 1 / terminal 2 miswire. Terminal 1 and terminal 2 are reversed, shorted, or shorted to terminal C or R.

Is it safe to keep using my heat pump with code Green LED: Solid on?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code Green LED: Solid on myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code Green LED: Solid on comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code Green LED: Solid on near me?

Aurora Star Tech Inc. repairs Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Daikin DX6VS/DZ6VS outdoor unit installation manual, p. 47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.