Daikin Error Code JC: Low pressure sensor connector X31A disconnected (Water Heater)

Updated · by Aurora Star Tech Inc.

Daikin error code JC on a water heater means: Low pressure sensor connector X31A disconnected. It is also called Daikin diagnostic code JC.

High severityWater HeaterMega-Q

Homeowner? What Daikin code JC means for you

Call a technician Your heating or cooling system is reporting: Low pressure sensor connector X31A disconnected. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code JC mean?

Subdivisions 06 and 07 (cascade unit) and 08 and 09 (heat source unit): the X31A low pressure sensor connector on A1P is disconnected.

Applies to: Cascade unit and heat source unit

Common causes of Daikin code JC

  • X31A connector disconnected
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Daikin Water Heater codes

CodeMeaning
J5J5 subcode 03: heat source X30A thermistor disconnected
J6J6 subcode 02
J7J7 subcodes 13 and 14: cascade unit X30A thermistor disconnected
J8J8 subcode 02
J9J9 subcode 02
JAHigh pressure sensor connector X32A disconnected
LCInverter communication connectors disconnected
P1Power supply voltage imbalance
U1Power wiring reverse phase or no power
U2Power supply voltage error, imbalance or phase loss
UCUC: duplicate cascade unit address
UETransmission to tank control board not established

All Daikin Water Heater error codes →

Daikin code JC: homeowner questions

What does Daikin code JC mean?

Low pressure sensor connector X31A disconnected. Subdivisions 06 and 07 (cascade unit) and 08 and 09 (heat source unit): the X31A low pressure sensor connector on A1P is disconnected.

Is it safe to keep using my heating or cooling system with code JC?

It depends on the cause. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code JC myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code JC comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code JC near me?

Aurora Star Tech Inc. repairs Daikin heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Daikin Mega-Q installation manual, p. 49. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.