Goodman Furnace Error Codes
131 Goodman Furnace error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.
Goodman Furnace error codes list
Find codes by Goodman model
Goodman/Amana *MVC96 (34.5 in. chassis)
*CVC960403BNB**CVC960603BNB**CVC960804CNB**CVC961005CNB**CVC961205DNB**MVC960403BNB**MVC960603BNB**MVC960803BNB**MVC960804CNB**MVC961005CNB**MVC961005DNB**MVC961205DNB*ACVC96AMVC96GCVC96GMVC96
Goodman/Amana GM9C96/AM9C96
AC9C96AM9C96AM9C960303ANGC9C96GM9C96GM9C960303AN
Goodman/Amana GM9S80/AM9S80
AC9S800403ANAC9S800603ANAC9S800804BNAC9S800805CNAC9S801005CNAM9S800403ANAM9S800603ANAM9S800603BNAM9S800604BNAM9S800803BNAM9S800804BNAM9S800804CNAM9S800805CNAM9S801005CNAM9S801205DNGC9S800403ANGC9S800603ANGC9S800804BNGC9S800805CNGC9S801005CNGM9S800403ANGM9S800603ANGM9S800603BNGM9S800604BNGM9S800803BNGM9S800804BNGM9S800804CNGM9S800805CNGM9S801005CNGM9S801205DN
Goodman/Amana GM9S96/AM9S96
AC9S960403BNAC9S960603BNAC9S960804CNAC9S961005CNAC9S961205CNAC9S961205DNAM9S920403ANAM9S920603BNAM9S920803BNAM9S920804CNAM9S920805CNAM9S921004CNAM9S921005CNAM9S921205DNAM9S960403ANAM9S960603BNAM9S960803BNAM9S960804CNAM9S960805CNAM9S961004CNAM9S961005CNAM9S961205DNGC9S960403BNGC9S960603BNGC9S960804CNGC9S961005CNGC9S961205CNGC9S961205DNGM9S920403ANGM9S920603BNGM9S920803BNGM9S920804CNGM9S920805CNGM9S921004CNGM9S921005CNGM9S921205DNGM9S960403ANGM9S960603BNGM9S960803BNGM9S960804CNGM9S960805CNGM9S961004CNGM9S961005CNGM9S961205DN
Goodman/Amana *MES9 single-stage
ACES96ACES960403BNAAACES960603BNAAACES960804CNAAACES961005CNAAACES961205DNAAAMES92AMES96AMES920403ANAAAMES920603BNAAAMES920803BNAAAMES920804CNAAAMES920805CNAAAMES921004CNAAAMES921005CNAAAMES921205DNAAAMES960403ANAAAMES960603BNAAAMES960803BNAAAMES960804CNAAAMES960805CNAAAMES961005CNAAAMES961205DNAAGCES96GCES960403BNAAGCES960603BNAAGCES960804CNAAGCES961005CNAAGCES961205DNAAGMES92GMES96GMES920403ANAAGMES920603BNAAGMES920803BNAAGMES920804CNAAGMES920805CNAAGMES921004CNAAGMES921005CNAAGMES921205DNAAGMES960403ANAAGMES960603BNAAGMES960803BNAAGMES960804CNAAGMES960805CNAAGMES961005CNAAGMES961205DNAAVCES96VCES960403BNAAVCES960603BNAAVCES960804CNAAVCES961005CNAAVMES96VMES960403ANAAVMES960603BNAAVMES960803BNAAVMES960804CNAAVMES961005CNAA
Goodman/Amana *MVC95/*CVC9 two-stage ComfortNet
GCVC90704CXGCVC90905DXGCVC91155DXGCVC950714CXGCVC950915DXGMVC950453BXGMVC950704CXGMVC950905CXGMVC950905DXGMVC951155DX
Furnace troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
- Cycles on limit (not lockout) All brands · Furnace
- Does not start All brands · Furnace
- Flame burns a few seconds then out All brands · Furnace
- Flame conditions table All brands · Furnace
- Heat exchanger leak All brands · Furnace
- High blower-door ACH50 (>3) All brands · Furnace
- High fuel consumption All brands · Furnace
- High stack temperature All brands · Furnace
- High stack temperature / low efficiency All brands · Furnace
- Indoor blower runs, outdoor unit dead All brands · Furnace
- Limit opens All brands · Furnace
- Locks out — oil but no ignition All brands · Furnace
- Low CO2 (<8 %) All brands · Furnace
- Low draft / blowback All brands · Furnace
- Modulating furnace won't modulate All brands · Furnace
- Negative house pressure, backdrafting, infiltration All brands · Furnace
- No heat All brands · Furnace
- No heat (ignition stage) All brands · Furnace
- Noisy All brands · Furnace
- Noisy registers, drafts, blower overamps/ECM noise, coil freezing All brands · Furnace
- Not running / fault code All brands · Furnace
- Oil + ignition OK but no flame All brands · Furnace
- Oil on floor All brands · Furnace
- Pressure switch open / stuck All brands · Furnace
- Puff-back / delayed ignition All brands · Furnace
- Reduced airflow, hot motor All brands · Furnace
- Reduced pressure, smoky shutdowns, lockouts All brands · Furnace
- Rollout switch tripped All brands · Furnace
- Short cycling All brands · Furnace
- Smoke, soot, odour, pulsation All brands · Furnace
- Starts but locks out — no oil at nozzle All brands · Furnace
- Too little / too much air All brands · Furnace
- Unsatisfactory heat (short cycles / uneven / not enough) All brands · Furnace
- Water flows with furnace off All brands · Furnace
- Active alarm display Goodman · Furnace
- Air filter maintenance Goodman · Furnace
- Airflow display in the Status Menu Goodman · Furnace
- Airflow lower than demanded, furnace runs on low stage when high stage is expected Goodman · Furnace
- Airflow setup for communicating and non-communicating outdoor units Goodman · Furnace
- Allowed installation positions Goodman · Furnace
- Alternate combustion air opening (upflow or horizontal) Goodman · Furnace
- Alternate electrical, gas and vent connections Goodman · Furnace
- Alternate vent/flue location (upflow or horizontal left) Goodman · Furnace
- Annual inspection checklist Goodman · Furnace
- App access code and alternate connection Goodman · Furnace
- Auxiliary alarm (condensate) switch wiring Goodman · Furnace
- Auxiliary limit control (location and purpose) Goodman · Furnace
- Auxiliary limit switch open (blower compartment) Goodman · Furnace
- Blower door interlock Goodman · Furnace
- Blower motor does not have enough information, fails to start 40 consecutive times Goodman · Furnace
- Blower motor fails to start after 10 consecutive tries Goodman · Furnace
- Blower motor horsepower mismatch Goodman · Furnace
- Blower motor loss of rotor control or high current trip Goodman · Furnace
- Blower motor operating in power, temperature or speed limit (reduced airflow) Goodman · Furnace
- Blower motor over or under voltage, or over temperature on power module Goodman · Furnace
- Burner flame appearance check Goodman · Furnace
- Bypass the inductor to test an ECM motor Goodman · Furnace
- Canadian vent system requirements Goodman · Furnace
- Check and adjust temperature rise Goodman · Furnace
- Check auxiliary limit control (blower housing) Goodman · Furnace
- Check blower (inducer) pressure switch Goodman · Furnace
- Check burner orifices Goodman · Furnace
- Check duct static pressure Goodman · Furnace
- Check ECM control/end bell Goodman · Furnace
- Check ECM high voltage power circuits Goodman · Furnace
- Check ECM low voltage control circuit Goodman · Furnace
- Check ECM motor windings Goodman · Furnace
- Check flame rollout switch Goodman · Furnace
- Check gas input by clocking the gas meter Goodman · Furnace
- Check induced draft blower motor Goodman · Furnace
- Check line voltage to the furnace Goodman · Furnace
- Check primary limit control Goodman · Furnace
- Check primary limit control (90% furnaces) Goodman · Furnace
- Check the hot surface igniter Goodman · Furnace
- Check thermostat and low voltage wiring Goodman · Furnace
- Check transformer and control circuit Goodman · Furnace
- Check transformer phasing on unmarked transformers Goodman · Furnace
- Check wiring Goodman · Furnace
- Checking unit grounding Goodman · Furnace
- Circulator blower motor not running when it should be Goodman · Furnace
- Clear an E0 lockout (3 ways) Goodman · Furnace
- Clearing the fault history Goodman · Furnace
- Clocking a gas meter Goodman · Furnace
- Code release number menu Goodman · Furnace
- Combustion and ventilation air Goodman · Furnace
- ComfortBridge memory chip (last resort) Goodman · Furnace
- ComfortNet data line check - Goodman *MVC95/*CVC9 Goodman · Furnace
- Concentric and side wall vent kits Goodman · Furnace
- Condensate drain system general rules Goodman · Furnace
- Condensate drainage system check Goodman · Furnace
- Condensate switch open Goodman · Furnace
- Connecting the CoolCloud app when the 3-digit code is not visible Goodman · Furnace
- Control display blank, furnace dead - Goodman/Amana 9-speed ECM furnaces Goodman · Furnace
- Counterflow drain trap clearance Goodman · Furnace
- Counterflow horizontal, left side down - drain setup Goodman · Furnace
- Counterflow horizontal, right side down - drain setup Goodman · Furnace
- Counterflow vertical - drain exit side Goodman · Furnace
- Customer bundle: auxiliary condensate switch wiring Goodman · Furnace
- Data not yet on network Goodman · Furnace
- Dehumidification wiring and logic Goodman · Furnace
- Delayed ignition - rough light-off Goodman · Furnace
- Delayed ignition check Goodman · Furnace
- Diagnostics: last six faults storage Goodman · Furnace
- Direct vent (dual pipe) routing and terminations Goodman · Furnace
- Direct vent (dual pipe) termination Goodman · Furnace
- Direct vent combustion air intake connection Goodman · Furnace
- Display blank, furnace dead - Goodman *MVC95/*CVC9 Goodman · Furnace
- Drain pan and freeze protection Goodman · Furnace
- Dual certification: non-direct and direct vent Goodman · Furnace
- Elbow dimensions for vent piping Goodman · Furnace
- Electrical connections and wiring harness rules Goodman · Furnace
- Electronic air cleaner (EAC) line voltage connection Goodman · Furnace
- Electrostatic discharge (ESD) precautions Goodman · Furnace
- Electrostatic discharge precautions for the integrated control module Goodman · Furnace
- External gas valve error (valve not energized when it should be) Goodman · Furnace
- Flame detected when no flame should be present Goodman · Furnace
- Flame sensor cleaning and signal check Goodman · Furnace
- Flame sensor microamp check Goodman · Furnace
- Flashback - burning inside the burner venturi Goodman · Furnace
- Flashback at ignition or burner shutoff Goodman · Furnace
- Fossil fuel application with a heat pump Goodman · Furnace
- Front cover pressure switch tube relocation (horizontal, left side down) Goodman · Furnace
- Furnace fails to operate, control LED shows no signal Goodman · Furnace
- Furnace in lockout - how to reset it Goodman · Furnace
- Gas pressure test mode (100% firing) Goodman · Furnace
- Gas valve (two-stage) and front cover pressure switch Goodman · Furnace
- General ECM blower checks Goodman · Furnace
- Grounding fault Goodman · Furnace
- Heating performance test Goodman · Furnace
- High altitude application (USA) Goodman · Furnace
- High fire and low fire gas pressure test (longer term) Goodman · Furnace
- High fire gas pressure test (temporary) Goodman · Furnace
- High stage pressure switch open, furnace on low stage only Goodman · Furnace
- High stage pressure switch stuck closed at start of heating Goodman · Furnace
- Horizontal installation: suspension, leveling and drain Goodman · Furnace
- Igniter fault or improper grounding Goodman · Furnace
- Induced draft and circulator blower motors Goodman · Furnace
- Integrated control module diagnostic LED Goodman · Furnace
- Integrated ignition control board checks Goodman · Furnace
- Internal gas valve error (valve energized when it should not be) Goodman · Furnace
- Invalid memory card data Goodman · Furnace
- Junction box relocation and wiring rules Goodman · Furnace
- Learn menu (communication network reset) Goodman · Furnace
- Line voltage electronic air cleaner (EAC) connection Goodman · Furnace
- Lockout after excessive ignition retries (3 total) Goodman · Furnace
- Loss of communication with circulator blower motor Goodman · Furnace
- Loss of flame after establishment Goodman · Furnace
- Low flame signal, furnace runs normally Goodman · Furnace
- Low stage pressure switch contacts not closed Goodman · Furnace
- Low stage pressure switch open, induced draft blower runs continuously Goodman · Furnace
- Low stage pressure switch stuck closed at start of heating Goodman · Furnace
- Measure and adjust manifold gas pressure (36J54 valve) Goodman · Furnace
- Measure inlet gas supply pressure Goodman · Furnace
- Minimum clearances and service access Goodman · Furnace
- Multiple direct vent furnaces at one termination Goodman · Furnace
- No heat - Goodman/Amana 9-speed ECM furnaces Goodman · Furnace
- No ignition - voltage checks at the ignition control Goodman · Furnace
- Non-direct vent (single pipe) termination Goodman · Furnace
- Non-direct vent: intake elbow requirement Goodman · Furnace
- Open fuse, no furnace operation Goodman · Furnace
- Open the furnace advanced menus from a ComfortNet thermostat Goodman · Furnace
- Pipe slope, support and transitions Goodman · Furnace
- Poor combustion / flame problems - Goodman/Amana GM9C96 Goodman · Furnace
- Primary (high) limit open, circulator blower runs continuously Goodman · Furnace
- Propane and high altitude conversion notes Goodman · Furnace
- Push button navigation on the control board Goodman · Furnace
- Reading the furnace model number Goodman · Furnace
- Reload model data with the memory card Goodman · Furnace
- Reset the ComfortNet network (learn button) Goodman · Furnace
- Reset the furnace control to factory defaults (rFd) Goodman · Furnace
- Resetting a furnace lockout Goodman · Furnace
- Reversed line polarity Goodman · Furnace
- Rollout switch open Goodman · Furnace
- Safety circuit overview Goodman · Furnace
- Set heat anticipator on room thermostat Goodman · Furnace
- Sharp sheet metal edges Goodman · Furnace
- Standard furnace vent and intake connections Goodman · Furnace
- Status Menu rotation Goodman · Furnace
- Temperature rise out of range - Goodman *MVC95/*CVC9 Goodman · Furnace
- Test the ECM motor with the UltraCheck-EZ diagnostic tool Goodman · Furnace
- Testing gas heat only with a heat pump installed Goodman · Furnace
- Thermostat mounting location Goodman · Furnace
- Thermostat placement Goodman · Furnace
- Thermostat setup: single stage heat and cool Goodman · Furnace
- Turn on dehumidification Goodman · Furnace
- Unit address shown at power-up Goodman · Furnace
- Upflow horizontal, left side down - alternate drain setup Goodman · Furnace
- Upflow horizontal, left side down - drain setup Goodman · Furnace
- Upflow horizontal, right side down - drain setup Goodman · Furnace
- Upflow vertical - drain exiting left side Goodman · Furnace
- Upflow vertical - drain exiting right side Goodman · Furnace
- Upflow vertical install - drain exit side Goodman · Furnace
- Use a single-stage thermostat (timed staging) Goodman · Furnace
- Valid equipment combinations Goodman · Furnace
- Vent piping cement and solvent safety Goodman · Furnace
- Vent termination heights and sealing Goodman · Furnace
- Vent/flue pipe sizing and elbow rules (non-direct vent) Goodman · Furnace
- Venting check when an existing furnace is removed from a shared vent Goodman · Furnace
- Venting restrictions and vent system check Goodman · Furnace
- View and clear the last 6 furnace faults Goodman · Furnace
- View and clear the last 6 stored faults (L6F) Goodman · Furnace
- Wiring replacement and grounding requirements Goodman · Furnace
Goodman Furnace specs and setup data
- Minimum recommended filter size Goodman · Furnace · Goodman/Amana GM9C96/AM9C96
- Normal status displays (7-segment) Goodman · Furnace · Goodman/Amana GM9S96/AM9S96
- Normal status displays (7-segment) Goodman · Furnace · Goodman/Amana GM9S80/AM9S80
- Normal status displays (7-segment) Goodman · Furnace · Goodman/Amana GM9C96/AM9C96
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.