Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code E015: PCB fault (Combi Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E015 on a combi boiler means: PCB fault. It is also called Navien diagnostic code E015.

High severityCombi BoilerNavien CH ASME

Homeowner? What Navien code E015 means for you

Call a technician Your combi boiler is reporting: PCB fault. The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
  • If only hot water is missing, check that the hot water tap is open far enough to start the heater.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E015 mean?

The control board reports a problem.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

Common causes of Navien code E015

  • Power supply problem
  • Power switch off or faulty
  • Faulty PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code E015

CH-180 ASMECH-210 ASMECH-240 ASME

Other Navien Combi Boiler codes

CodeMeaning
E008DHW outlet sensor shorted
E009Fan motor fault
E010Air pressure fault
E011High pressure on the heating side
E012Flame loss
E013Pump fault
E016Heat exchanger overheat (overheating of heat exchanger)
E018Heating return sensor open
E019Heating return sensor shorted
E021DHW cold inlet sensor open
E022DHW cold inlet sensor shorted
E027Air pressure sensor fault

All Navien Combi Boiler error codes →

Navien code E015: homeowner questions

What does Navien code E015 mean?

PCB fault. The control board reports a problem.

Is it safe to keep using my combi boiler with code E015?

It depends on the cause. The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code E015 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E015 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E015 near me?

Aurora Star Tech Inc. repairs Navien combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Error Code Guide, p.43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977