Navien Combi Boiler: Hot water not hot enough or too hot
Hot water not hot enough or too hot on a Navien combi boiler: DHW temperature is off from what the customer wants.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
Common causes of hot water not hot enough or too hot
- Set temperature too low or too high
- Cross-connection between hot and cold lines
How to fix hot water not hot enough or too hot: step by step
- Check the DHW set temperature on the remote (86-120°F normal range, up to 140°F by pressing DHW and Heating together).
- If water is still lukewarm, look for cross plumbing between the cold and hot lines.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.