CH series E028 water leak / repeated low pressure - full check on a Navien combi boiler: E028 shows if heating pressure stays at 7.3 psi or less for 5 minutes, or drops to 7.3 psi again within 2 hours after an auto fill. It is held off for the first 72 hours after first power-up. Manual reset.

Homeowner with a combi boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers

Common causes of ch series e028 water leak / repeated low pressure - full check

  • Leak inside the boiler or in the heat exchanger
  • Leak in system piping
  • Auto feeder valve plugged or dead
  • Pressure sensor fault
  • Cold water supply off or frozen

How to fix ch series e028 water leak / repeated low pressure - full check: step by step

  1. Turn off power before unplugging connectors or measuring resistance.
  2. Look for leaks inside the unit and on the system piping.
  3. Heat exchanger leak test: set trial mode (DIP 2-2 ON). If water keeps running out the condensate hose, the heat exchanger is leaking.
  4. Auto feeder valve: clean its filter. Drain some water from the pump drain and see if it refills.
  5. Check 120 VAC at CN21 pins 1 and 3 when filling. Power and no fill = replace the valve. No power = PCB.
  6. Press reset: fill should finish within 5 minutes.
  7. Check the cold water supply is open and not frozen.
  8. If all checks pass, replace the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Combi Boiler codes

Models

CH-180 ASMECH-210 ASMECH-240 ASME

Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.22 28 Error p.100-101. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977