Navien Combi Boiler: CH series E002 low water pressure / auto fill – full check
CH series E002 low water pressure / auto fill - full check on a Navien combi boiler: E002 shows when system pressure is low. The boiler stops and the auto feeder valve tops up. Fill starts at 7.3 psi or less for 4 seconds and stops at about 12 psi (depends on setting). If still under 7.4 psi after 3 minutes, filling stops. The error clears by itself once pressure is back.
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
Common causes of ch series e002 low water pressure / auto fill - full check
- Cold water valve closed or frozen
- Auto feeder valve filter plugged or valve dead
- Water leaking out the condensate hose (left drain valve on main HX open, or leaking HX)
- Leak in heating piping or distributor
- Pressure sensor or display fault
How to fix ch series e002 low water pressure / auto fill - full check: step by step
- Turn off power before unplugging connectors or measuring resistance.
- Open a cold tap to confirm cold supply is on and not frozen.
- Check the auto feeder valve filter for debris.
- Check 97-138 VAC on the auto feeder valve wires (Blue-Blue) when it should fill. Power there and no fill = replace the valve. No power = PCB.
- If water runs out the condensate hose, check the drain valve at the lower left of the main heat exchanger, then check the heat exchanger for leaks.
- Frequent E002: look for leaks at pipe joints and the distributor, and check the expansion tank. Tell the customer (this also leads to E028).
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.3 02 Error p.59-60; 4.6.21 Auto Feeder Valve p.53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.