Navien Combi Boiler: Annual maintenance check
Annual maintenance check on a Navien combi boiler: Check list for the yearly visit at the start of the heating season.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
How to fix annual maintenance check: step by step
- Turn off power before opening the cabinet.
- Check the condensate drains freely and clean out sediment. Every 6 months pull the condensate hose and clear debris.
- Check air vents and relief valves are not weeping.
- Inspect the whole vent for leaks, clean the vent screens, and make sure nothing blocks the intake or exhaust ends.
- Make sure PVC vent joints are tight. Replace cracked or loose fittings.
- Look at the flame through the burner window: you want a 1/2 to 3/4 in. blue flame. Do not open the burner compartment; if the burner needs cleaning, a Navien-approved tech does it.
- Keep the area clear of combustibles and flammable vapors.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH-180/210/240 ASME Installation Manual (ch-asme-installation-manual-en), Maintenance, p.65. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.