Navien Combi Boiler: CH series E030 exhaust high limit – full check
CH series E030 exhaust high limit - full check on a Navien combi boiler: E030 shows when the exhaust limit switch at the top of the exhaust duct opens for 1 second. It opens at 149°F (65°C). The boiler locks out and post-purges. The code clears by itself once the switch closes.
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
Common causes of ch series e030 exhaust high limit - full check
- Exhaust running hot (scaled or dirty heat exchanger)
- Exhaust limit switch failed
- Bad PCB
How to fix ch series e030 exhaust high limit - full check: step by step
- Turn off power before unplugging connectors or measuring resistance.
- Let it cool, then pull the switch and check it with a meter. Very high resistance (MOhm) when cool = bad switch.
- The code table says to clean the inlet water filter and flush the heat exchanger if it trips from heat.
- If the switch is good, replace the PCB.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.23 30 Error p.102; 5.1 p.55. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.