Navien Combi Boiler: No space heating – Navien NCB-H

Updated · by Aurora Star Tech Inc.

No space heating - Navien NCB-H on a Navien combi boiler: No space heat on a Navien NCB-H combi, but the unit has power and the display is on. This one fools people, because the combi puts domestic hot water first, so the heat can seem dead when someone is running a shower. So start with the simple things like power, set temperature and hot water use. If heating performance has dropped, look at air in the system and the boiler pump. A clogged heating-side filter is the other usual find.

Homeowner with a combi boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien NCB-H combi boilers: NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H

Common causes of no space heating - navien ncb-h

  • No power or unit in standby
  • Unit is busy making DHW (DHW has priority)
  • Restricted heating-side filter
  • Set temperature too low
  • Air in the heating system or a weak boiler pump

How to fix no space heating - navien ncb-h: step by step

  1. Check power to the unit and that it is plugged into a grounded 120 V outlet, press the Power button to turn it on
  2. Raise the space heating set temperature
  3. Remember heating stops while the unit is making domestic hot water, so close all hot taps and wait
  4. Clean the space-heating return water filter, isolate and relieve pressure first
  5. If heating performance has dropped, also check for air in the system and check the boiler pump in Test Mode
  6. Check the display for any error code
  7. Call a licensed tech for gas side or sealed-combustion issues
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Combi Boiler codes

Models

Navien CH ASME

CH-180 ASMECH-210 ASMECH-240 ASME

Navien NCB-H

NCB-190/060HNCB-190/080HNCB-240/110HNCB-240/130HNCB-250/150H

Navien NFC-H

NFC-250/175HNFC-250/200H

Source: Navien NCB-H User's Information Manual Version 1.0 (April 2024), 5.1 Solving Basic Problems, p.24 and 4.4 Cleaning the Heating Return Water Filter, p.16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977