Navien Combi Boiler: CH series E035 gas pressure sensor (GPS) – full check
CH series E035 gas pressure sensor (GPS) - full check on a Navien combi boiler: E035 shows when the GPS output sits at about 0.1 V or 4.5 V for 5 seconds. Manual reset.
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
Common causes of ch series e035 gas pressure sensor (gps) - full check
- No gas (valve closed, meter problem)
- GPS hose kinked or torn
- Failed GPS
- Bad PCB
How to fix ch series e035 gas pressure sensor (gps) - full check: step by step
- Gas work: licensed gas tech only. Turn off gas and power before opening the gas train, and leak-test every joint you opened.
- Check the gas valve is open and the meter is OK. Measure the gas pressure drop at max fire.
- Check the GPS hose for kinks or tears.
- GPS power: 5 VDC (red-black). GPS signal: 0.3-4.5 VDC (white-black). The flowchart gives about 0.2-0.6 VDC with the gas valve on and 1-4 VDC with it off at CN7.
- Bad readings = replace the GPS. Good readings and still E035 = PCB.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.24 35 Error p.103-104; 4.6.12 GPS p.43. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.