Navien Combi Boiler: No space heating
No space heating on a Navien combi boiler: The house is not heating but no error code shows.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
Common causes of no space heating
- Set temperature too low
- Remote off or unit in Stand By
- 24 hour timer blocking the call
- Unit busy with a DHW call
- Heating-side strainer blocked
- Pre-heating mode on
How to fix no space heating: step by step
- Raise the heating set temperature on the remote.
- Make sure the unit has power at the right voltage, the remote is ON and the heating button is active.
- Check the clock and the 24 hour timer blocks.
- Wait out a DHW call. Heating is held off during DHW and there is about a 3 minute delay when switching back.
- Clean the space heating strainer (remove the clip, wash the screen, refit).
- If the pre-heating icon is blinking, heating is in stand by until pre-heat ends.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.