Navien Combi Boiler: CH series E040 outdoor sensor shorted – full check
CH series E040 outdoor sensor shorted - full check on a Navien combi boiler: E040 shows when the outdoor sensor reads 122°F (50°C) or more with the boiler on.
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
Common causes of ch series e040 outdoor sensor shorted - full check
- Outdoor sensor wire shorted or connector bad
- Failed outdoor sensor
- Bad PCB
How to fix ch series e040 outdoor sensor shorted - full check: step by step
- Turn off power before unplugging connectors or measuring resistance.
- Check the outdoor sensor wiring and plug.
- Test the sensor and replace if bad.
- If the sensor is good, replace the PCB.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.27 40 Error p.107. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.