CH series E015 PCB error - full check on a Navien combi boiler: E015 means the board found a fault in its own circuit.

Homeowner with a combi boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers

Common causes of ch series e015 pcb error - full check

  • Failed PCB
  • Supply voltage out of range
  • Electrical noise on the ground

How to fix ch series e015 pcb error - full check: step by step

  1. Turn off power before unplugging connectors or measuring resistance.
  2. Measure the outlet: 97-138 VAC.
  3. Press reset. If it comes back normal, watch it.
  4. Test for ground noise: tape over the ground pin at the receptacle as a short test only, and see if the board behaves. Restore the ground right after.
  5. If voltage is fine and the fault stays, replace the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Combi Boiler codes

Models

CH-180 ASMECH-210 ASMECH-240 ASME

Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.15 15 Error p.86. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977