Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Combi Boiler: Cleaning the intake air filter

Updated · by Aurora Star Tech Inc.

Cleaning the intake air filter on a Navien combi boiler: A plugged intake filter stops the boiler and brings up code 10. Clean it every 3 to 4 months.

Homeowner with a combi boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

Common causes of cleaning the intake air filter

  • Dust or pollen on the intake filter

How to fix cleaning the intake air filter: step by step

  1. Turn off power before opening the cabinet.
  2. Find the filter above the fan, under the intake air duct, top left of the cabinet.
  3. Remove the one Phillips screw and pull the filter frame out toward you.
  4. Take the screen out of the plastic frame and clean it with a soft brush and water.
  5. Refit the screen, put the frame back under the intake duct and refit the screw.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Combi Boiler codes

Models

CH-180 ASMECH-210 ASMECH-240 ASME

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Cleaning the Intake Air Filter, p.37. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair