Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Combi Boiler: No hot water at the tap

Updated · by Aurora Star Tech Inc.

No hot water at the tap on a Navien combi boiler: Water does not come out hot, or nothing comes out when a hot tap is opened.

Homeowner with a combi boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

Common causes of no hot water at the tap

  • Shut-off valve on the hot or cold line closed
  • Dirty cold water inlet filter
  • Unit frozen
  • Tap not open enough (needs at least 0.5 GPM)
  • An error code on the remote

How to fix no hot water at the tap: step by step

  1. Check the remote for a flashing error code and look it up.
  2. Make sure the shut-off valves on the hot and cold lines are open.
  3. Clean the cold water inlet filter.
  4. Open the tap more. The unit needs at least 0.5 GPM to fire.
  5. If the inlet pipe is frozen, thaw it with a hair dryer or heat gun.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Combi Boiler codes

Models

CH-180 ASMECH-210 ASMECH-240 ASME

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977