Navien Combi Boiler: No hot water at the tap
No hot water at the tap on a Navien combi boiler: Water does not come out hot, or nothing comes out when a hot tap is opened.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
Common causes of no hot water at the tap
- Shut-off valve on the hot or cold line closed
- Dirty cold water inlet filter
- Unit frozen
- Tap not open enough (needs at least 0.5 GPM)
- An error code on the remote
How to fix no hot water at the tap: step by step
- Check the remote for a flashing error code and look it up.
- Make sure the shut-off valves on the hot and cold lines are open.
- Clean the cold water inlet filter.
- Open the tap more. The unit needs at least 0.5 GPM to fire.
- If the inlet pipe is frozen, thaw it with a hair dryer or heat gun.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.