Viessmann Error Code P6: Compressor low-pressure protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code P6 on a mini-split means: Compressor low-pressure protection. It is also called Viessmann diagnostic code P6.

High severityMini-SplitVitocal IND-F

Homeowner? What Viessmann code P6 means for you

Call a technician Your ductless mini-split is reporting: Compressor low-pressure protection. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code P6 mean?

Compressor suction pressure is too low. Operation lamp and timer lamp both flash, 7 times.

Applies to: Outdoor unit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Mini-Split codes

CodeMeaning
P0Inverter module (IPM) fault
P1Over or under voltage protection
P2Compressor top overheat (OLP)
P3Low outdoor temperature cut-off in heating
P4Compressor drive fault
P5Mode conflict
P7IPM temperature sensor fault
PC0ACondenser high temperature protection
PC 0ACondenser high temperature protection
PC0FPFC module protection
PC 0FPFC module protection
PC0LOutdoor temperature too low

All Viessmann Mini-Split error codes →

Viessmann code P6: homeowner questions

What does Viessmann code P6 mean?

Compressor low-pressure protection. Compressor suction pressure is too low. Operation lamp and timer lamp both flash, 7 times.

Is it safe to keep using my ductless mini-split with code P6?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code P6 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code P6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code P6 near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSFA and DLFLFA installation instructions, p. 14. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.