Viessmann Error Code PC 11: Outdoor main control board DC bus high voltage protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC 11 on a mini-split means: Outdoor main control board DC bus high voltage protection. It is also called Viessmann diagnostic code PC 11.

High severityMini-SplitVitocal 100-S · DLCURA

Homeowner? What Viessmann code PC 11 means for you

Call a technician Your ductless mini-split is reporting: Outdoor main control board DC bus high voltage protection. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC 11 mean?

DC bus voltage on the outdoor main control board is too high.

Applies to: DLCURA 18-60 outdoor unit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code PC 11

Show all 22 models

36AAK48AAK58AAK80ES(N,L)80ESUDLCURAH18AAKDLCURAH18ABKDLCURAH24AAKDLCURAH24ABKDLCURAH30AAKDLCURAH30ABKDLCURAH36AAKDLCURAH36ABKDLCURAH48AAKDLCURAH48ABKDLCURAH60AAKDLCURAH60ABKFEM4FVM4X48***LFVM4X60***LFXM4X48**ALFXM4X60**AL

Other Viessmann Mini-Split codes

CodeMeaning
PC 06Compressor discharge temperature protection
PC08Outdoor over-current protection
PC 08Current overload protection
PC10Low AC supply voltage
PC 10Outdoor unit low AC voltage protection
PC11AC supply voltage protection (over voltage)
PC12DC bus high voltage / 341 MCE error
PC 12DC bus high voltage protection / 341 MCE error
PC30High pressure protection
PC 30High pressure protection
PC31Low pressure protection
PC 31Low pressure protection

All Viessmann Mini-Split error codes →

Viessmann code PC 11: homeowner questions

What does Viessmann code PC 11 mean?

Outdoor main control board DC bus high voltage protection. DC bus voltage on the outdoor main control board is too high.

Is it safe to keep using my ductless mini-split with code PC 11?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PC 11 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC 11 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC 11 near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann DLCURA service manual, p. 25 (no detail page listed). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.