Viessmann Error Code PC 03: High or low pressure protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC 03 on a mini-split means: High or low pressure protection. It is also called Viessmann diagnostic code PC 03.

High severityMini-SplitVitocal IND-F

Homeowner? What Viessmann code PC 03 means for you

Call a technician Your ductless mini-split is reporting: High or low pressure protection. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC 03 mean?

Shown as flashing LED, 7 times. See page 27.

Applies to: Refrigerant circuit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Mini-Split codes

CodeMeaning
PC 0LLow ambient temperature protection
PC00Inverter module (IPM) protection
PC 00IPM malfunction or IGBT over-current protection
PC 01Over-voltage or under-voltage protection
PC 02Compressor top temperature or IPM high temperature protection
PC03Pressure protection
PC04Inverter compressor drive error
PC 04Inverter compressor drive error
PC06Discharge temperature protection
PC 06Compressor discharge temperature protection
PC08Outdoor over-current protection
PC 08Current overload protection

All Viessmann Mini-Split error codes →

Viessmann code PC 03: homeowner questions

What does Viessmann code PC 03 mean?

High or low pressure protection. Shown as flashing LED, 7 times. See page 27.

Is it safe to keep using my ductless mini-split with code PC 03?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PC 03 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC 03 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC 03 near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal IND-F DLFSFBH service manual, p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.