General: Wide temperature swing / overshoot / lag
Wide temperature swing / overshoot / lag on a general: The wide swings and overshoot I run into usually come from a thermostat anticipator set wrong. If it's set too high for the control current, the stat heats up slowly and the room overshoots before it shuts the call off. A large differential or a line-voltage stat will give you the same lag, so I check those before blaming the equipment.
Common causes of wide temperature swing / overshoot / lag
- Anticipator mis-set, a rating that's too high makes the stat heat up slowly
- Differential set too large
- Line-voltage thermostat with coarse control
How to fix wide temperature swing / overshoot / lag: step by step
- Measure the actual control current with a meter
- Set the anticipator to the measured control current
- Look at the differential setting and tighten it if it's adjustable
- If it's a line-voltage stat, consider a low-voltage stat with a relay
- Consider an electronic thermostat for tighter control
- Watch a full cycle and confirm the swing has come in
If the unit shows an error code, look it up: Navien General codes Trane General codes
Source: General HVAC service practice — verify per model. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.