General: Negative pressure / drafts / spillage
Negative pressure / drafts / spillage on a general: Negative pressure in the house. Combustion appliance competes with fans, dryer and exhaust for air. Result is drafts, backdrafting and spillage. Treat spillage as a CO risk until proven otherwise.
Common causes of negative pressure / drafts / spillage
- Combustion appliance drawing house air
- Exhaust fans, dryer and range hood pulling more air out than comes in
- No makeup air supply
How to fix negative pressure / drafts / spillage: step by step
- Test for spillage at the draft hood or flue with all exhaust fans and the dryer running
- Test the room for CO
- Check the flue and chimney for blockage
- Add a makeup air unit, either a return-duct damper type or a mechanical-room type
- Retest draft and spillage after the install
- Have a licensed gas or oil tech do the final verification
If the unit shows an error code, look it up: Navien General codes Trane General codes
Source: General HVAC service practice — verify per model. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.