Navien General: Main panel button combinations
Main panel button combinations on a Navien general: Long presses are held for more than 3 seconds. Several combinations open service modes.
Applies to: WEC600
How to fix main panel button combinations: step by step
- Back + OK, long press: enter Install Check Mode.
- Back + Next, long press: enter Installer Setting Mode to view status info, run forced flushing, run forced CIP and reset errors.
- Back + OK + Next, long press: enter Reset Mode to reset the filter cartridge period and the CIP tank level.
- Back long press: skip initial regeneration and CIP mode steps.
- Next long press: set the time and the CIP operation time.
- OK long press: show feedwater TDS, product water TDS and cumulative treated water volume after CIP.
- Power long press: power the WEC on or off. When off, the internal bypass valve opens to pass feedwater.
If the unit shows an error code, look it up: Navien General codes
More button combinations tips for general
Source: Navien WEC Series service manual, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.