Navien General: Pipe grounding around the WEC
Pipe grounding around the WEC on a Navien general: The WEC section of pipe is electrically insulated, so the piping must be grounded to prevent corrosion.
Applies to: WEC600
Common causes of pipe grounding around the wec
- Insulating effect of the WEC section
- Plastic pipe sections
How to fix pipe grounding around the wec: step by step
- Ground both ends of the WEC pipe section: the inlet side of the sediment filter and the outlet side of the carbon block filter.
- If any section uses plastic pipe, add grounding to that section.
- Follow NEC 250.104 for all additional grounding.
If the unit shows an error code, look it up: Navien General codes
Source: WEC Series service manual, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.